FUNCTION CODE
LOCAL PROGRAMMING
31
MODIFY KEYPAD ACCESS CODE
AND CARD NUMBER (RADIO
TRANSMITTER NUMBER)
• You must know the keypad access
code to modify this field.
• The keypad access code cannot be
modified. You must delete it using
Function Code 32.
• Card number can be modified.
Step 1
Log on to programming mode (see section 3.1). The display shows
Step 2
Enter Function Code 31 then press # and the display shows
Step 3
Enter the 4-digit keypad access code to be modified then press #, the display
shows
if the keypad code is valid
and proceed to step 4
OR
if the keypad code is
invalid, proceed to step 2 or
step 10
Step 4
Enter the card number or radio transmitter number (00001 - 65535) (leave
this field blank if no Card Reader installed on the system) then press #, the
display shows
if door 2 is set for mode 1 (door control). If door 2 is set other than mode 1,
proceed to step 6.
Step 5
Enter 1=Relay 1 (Door 1) , 2=Relay 2 (Door 2), 3=Both then press #, the
display shows
Step 6
Enter 1-3 then press #, the display shows
Step 7
Enter the Time Zone (s) programmed on Function Code 13 (0-9) then
press #, the display shows
Step 8
Enter 1=YES then press # and proceed to step 6 or 0=NO then press # and
the display shows
Step 9
Enter the name up to 12 characters then press #, the display shows
Pach and Company
Chapter 3
Page 24
AeGIS 9000 Series
PROGRAMMING
SELECT PROGRAM
ENTER: _ _ PRESS #
Access Code to
modify: _ _ _ _
CARD No:
ENTER: _ _ _ _ _ PRESS#
No such a CODE!
USE [30] TO ADD
Door 1 or Door 2
3 for both: _
TimeZone section
3 MAX [1-3]: _
Which Time Zone
[0-9] : _
Another sction
(1=YES) (0=NO): _
CODE HOLDER NAME
_ _ _ _ _ _ _ _ _ _ _ _
SELECT PROGRAM
ENTER: _ _ PRESS #