1 menu item 1: batch accumulate enable/disable, 2 menu items – Nova-Tech LMI Series HH Metering Pump User Manual
Page 34

34
13.1 Accessing the Setup Menu
To access the Setup Menu, ensure that the pump is OFF and in the
Internal mode. Using the
(Up) key, bring the stroke rate to 100
SPM. At this point, keep the
(Up) key pressed for five (5)
seconds. The LCD screen then displays the current software
revision, indicating that you have entered the Menu mode
.
Press the
I
N
T
T
MODE
E
X
(Mode) key to scroll through the Menu Items. Use
the
(Up) or
(Down) key to enable or disable menu
functions and program values.
To exit the Menu mode, press the
START
STOP
(Start/Stop) key. Or, if no
keys are pressed for 13 seconds, the display reverts to
MIN
INT
.
13.2 Menu Items
13.2.1 Menu Item 1: Batch Accumulate Enable/Disable
Batch Accumulate may be enabled (1)
or disabled (0)
. Use the
(Up) or
(Down) key to change the
selection.