beautypg.com

0 external control modes for hh9, The display will alternate between spm and off – Nova-Tech LMI Series HH Metering Pump User Manual

Page 25

background image

25

11.5 Low-Level Switch (P/N 29190)

When the Low-Level Switch is fitted to the pump and a fault

condition exists, the "E1" error code will flash on the LCD screen

MIN

INT

.

For more information on the Low-Level Switch, see the Low-
Level Switch Assembly information sheet (P/N 1368).

When a fault condition exists, the pump is stopped and the alarm
and computer alarm lines are activated to allow remote monitoring.
After clearing the fault (by filling the tank), the pump will
automatically restart.

12.0 External Control Modes for HH9

To access the pulse divide, pulse multiply or milliamp response, the

pump must be changed from Internal (manual) mode to External

mode. To do this, first be sure the pump is stopped. Press the

I

N

T

T

MODE

E
X

(Mode) key and hold it for three (3) seconds. The LCD screen

displays the last External mode that was programmed. If this is the

first time the pump has been put in the External mode, the factory

default will be displayed on the LCD screen. The factory default

mode is "External Pulse Divide" with a divide value of one (1)

EXT

:

. The display will alternate between SPM and OFF.