Nova-Tech Digi–Sense 12-Channel Benchtop Scanning Thermometer User Manual
Page 34

33
Front panel displays and controls continued
How to set trigger type
How to set trigger type
A trigger (contact between pins 1 and 2 of the trigger) can be set to:
•
pulse print (print one record when trigger contact is closed).
•
S/S (start/stop) PRINT (equivalent to toggling PRINT on while
trigger contact is closed).
•
pulse STORE (equivalent to pushing STORE to log one record).
•
S/S (start/stop) STORE (equivalent to pushing LOG to continu-
ously log records while trigger contact is closed).
+ -
A L A R M
E X I T
MENU
1
S T O R E
2
L O G
3
R E C A L L
4
P R I N T
5
M A X
6
M I N
7
A V G
8
H O L D
9
S C A N
1b
1, 3b
3a
1a
2
0
CLEAR
The default setting is OFF.
To set or adjust the trigger type:
1. Push MENU until TRIGGER 1a is displayed and the current
setting 1b (OFF, STORE or PRINT) flashes.
2. Push the Up or Down arrow keys to scroll between OFF, STORE
and PRINT.
3a. Push EXIT to save the setting and return to scanning, or
3b. Push MENU to switch to the next setup topic (set trigger mode).
BA 32-36
10/12/01, 11:04 AM
33
- B4000-16 (28 pages)
- B4000-M (23 pages)
- Foxx Life Sciences (2 pages)
- CON 700 (24 pages)
- pH-CON 700 (32 pages)
- 2700 Series Benchtop Meters (60 pages)
- Oakton Testr 35 (6 pages)
- 4066, 4067, 4068, 4069, 4161, 4162, 4173, 4174, 4176, 4177 Control Company (4 pages)
- 4065, 4175, 4270, 4271, 4274, 4565, 4570, 4574 Control Company (4 pages)
- 4170 Control Company (4 pages)
- WD-35653-15 (3 pages)
- WD-35653-13 (1 page)
- pH-CON 300 (26 pages)
- pH-CON 10 (29 pages)
- CON 6+ (40 pages)
- 4070 Control Company (1 page)
- WD-00653-00 Zero Oxygen (1 page)
- pH-Dissolved Oxygen Meter (35 pages)
- DO 700 (36 pages)
- DO 6+ (48 pages)
- Foxx Autofil Bottle Top Filtration (2 pages)
- Foxx Autofil Centrifuge Funnel and Stand (2 pages)
- Foxx Autofil Laboratory Storage Bottles (2 pages)
- Foxx Autofil Pedestal and Cradle Ring (4 pages)
- RITEFLOW FLOWMETERS AND KITS (16 pages)
- Roto-Flo Flow Indicators 19937 Series (1 page)
- Leveling Base Kit (each) H40404-1000 (1 page)
- Taylor M-3000 TTi3000 Colorimeter Series (28 pages)
- Bel-Art Magnetic Stirring Bars Selection & Use Guide (4 pages)
- VISPOL-Series Polarimeters (2 pages)
- UniPol L-Series Polarimeters (4 pages)
- iPR-Series (8 pages)
- Atago AP-300 Series Polarimeter (4 pages)
- Foxx Heavy Duty Vacuum Bottle (2 pages)
- pH 700 Ion 700 (18 pages)
- pH Tutor Benchtop Meter (2 pages)
- pH 4.01 Buffer (1 page)
- pH 5+ (28 pages)
- pH 11 (76 pages)
- pH 300 (24 pages)
- 4080 TRACEABLE HUMIDITY_TEMPERATURE DEW POINT METER (2 pages)
- 4088 TRACEABLE HYGROMETER_THERMOMETER (1 page)
- 3651 TRACEABLE ANEMOMETER_HYGROMETER_THERMOMETER_DEW POINT PEN (2 pages)
- 3652 TRACEABLE ANEMOMETER_HYGROMETER_THERMOMETER_DEW POINT BAROMETER PEN (3 pages)
- Sibata 6168 Filter Holders (1 page)