Factory default settings – Nova-Tech DO 6+ User Manual
Page 39

Instruction Manual
DO 6+
- 33 -
9. FACTORY DEFAULT SETTINGS
MENU DESCRIPTION
OPTIONS DEFAULT
COF.1
Configuration Setup Menu
A.ATC
Automatic Temperature Compensation
YES / NO
YES
b.DO
DO Concentration Units
mg/L or ppm
mg/L
CAL.2
Calibration Data
View only
_ _ _ _
ELE.3
Electrode Data Menu
FACT
Electrode Slope Factor
View only
1.000
OFS
Viewing the % Saturation offset
adjustment.
View only
0.0%
HI.mV
View mV Value at 100% Saturation
View only
50 mV
LO.mV
View mV Value at 0% Saturation
View only
0 mV
AtO.4
Automatic Power Off
YES / NO
YES
rSt.5
Reset to Factory Default Menu
A.CAL
Selection of Calibration Reset
NO / YES
NO
b.USR
Selection of User Reset
NO / YES
NO
OFS.6
% Saturation Offset Adjustment
+/- 10.0%
0.0%
DPr.7
Dissolved Oxygen Parameters Menu
A.HG
Pressure Adjustment in mm Hg
500 – 1499
760
A.PA Pressure
Adjustment
in kPa
66.6 - 199.9
101.3
b.SAL
Salinity Adjustment in ppt
0.0 - 50.0
0.0
Manual Temperature Compensation
0.0 - 50.0 °C
25.0°C
- B4000-16 (28 pages)
- B4000-M (23 pages)
- Foxx Life Sciences (2 pages)
- CON 700 (24 pages)
- pH-CON 700 (32 pages)
- 2700 Series Benchtop Meters (60 pages)
- Oakton Testr 35 (6 pages)
- 4066, 4067, 4068, 4069, 4161, 4162, 4173, 4174, 4176, 4177 Control Company (4 pages)
- 4065, 4175, 4270, 4271, 4274, 4565, 4570, 4574 Control Company (4 pages)
- 4170 Control Company (4 pages)
- WD-35653-15 (3 pages)
- WD-35653-13 (1 page)
- pH-CON 300 (26 pages)
- pH-CON 10 (29 pages)
- CON 6+ (40 pages)
- 4070 Control Company (1 page)
- WD-00653-00 Zero Oxygen (1 page)
- pH-Dissolved Oxygen Meter (35 pages)
- DO 700 (36 pages)
- Foxx Autofil Bottle Top Filtration (2 pages)
- Foxx Autofil Centrifuge Funnel and Stand (2 pages)
- Foxx Autofil Laboratory Storage Bottles (2 pages)
- Foxx Autofil Pedestal and Cradle Ring (4 pages)
- RITEFLOW FLOWMETERS AND KITS (16 pages)
- Roto-Flo Flow Indicators 19937 Series (1 page)
- Leveling Base Kit (each) H40404-1000 (1 page)
- Taylor M-3000 TTi3000 Colorimeter Series (28 pages)
- Bel-Art Magnetic Stirring Bars Selection & Use Guide (4 pages)
- VISPOL-Series Polarimeters (2 pages)
- UniPol L-Series Polarimeters (4 pages)
- iPR-Series (8 pages)
- Atago AP-300 Series Polarimeter (4 pages)
- Foxx Heavy Duty Vacuum Bottle (2 pages)
- pH 700 Ion 700 (18 pages)
- pH Tutor Benchtop Meter (2 pages)
- pH 4.01 Buffer (1 page)
- pH 5+ (28 pages)
- pH 11 (76 pages)
- pH 300 (24 pages)
- 4080 TRACEABLE HUMIDITY_TEMPERATURE DEW POINT METER (2 pages)
- 4088 TRACEABLE HYGROMETER_THERMOMETER (1 page)
- 3651 TRACEABLE ANEMOMETER_HYGROMETER_THERMOMETER_DEW POINT PEN (2 pages)
- 3652 TRACEABLE ANEMOMETER_HYGROMETER_THERMOMETER_DEW POINT BAROMETER PEN (3 pages)
- Sibata 6168 Filter Holders (1 page)