Camptr1, Camera video surge protection, Installation – Nitek CAMPTR1 User Manual
Page 2: Specification

CAMPTR1
Camera Video Surge Protection
INSTALLATION
The CAMPTR1 must be properly installed to insure maximum protec-
tion. The function of the CAMPTR1 is to allow a surge to be routed to ground
and to clamp the protected equipment inputs to a minimum voltage.
There are three key points to remember when installing the CAMPTR1.
First provide a low impedance connection between the CAMPTR1 and your
protected equipment. This is best done by keeping the PROTECTED cable
connection as short as possible.
Second the system should use a single ground point. Connect the
grounding wire of the CAMPTR1 to a single ground point. A single ground point
is a proper building ground or earth ground to which equipment grounds are
connected. Ideally the protected equipment should be isolated from ground. If
the CAMPTR1 and the protected equipment are both grounded you will provide
a parallel path to ground and a portion of the surge current can flow though that
path.
Finally, the UNPROTECTED cable should not be crossed with the
PROTECTED cable. Crossing cables could provide a path for surge currents
to bypass the CAMPTR1 protection circuits.
SPECIFICATION
Size
1.5"H x 1.3"W x 8"D
Power Requirements
NONE REQUIRED
Connection Method
Female BNC connectors
Clamping Voltage
2.8v
Video Insertion Loss
<0.2dB
Impedance
50 or 75 ohms
Temperature
-40C to +85C
Frequency
DC to 10 MHz