Parts of the ER1651U (Rear Panel)
Device Mounting Options
The ER1651U is to be rack mounted. Use the included mounting ears when rack mounting the unit, and be sure to
follow these guide lines.
a. Operating Ambient - Do not install the unit in an assembly where the ambient temperature could exceed
52°C (125°F). NOTE: the ambient temperature in a closed or multi-unit rack assembly could greatly exceed
the ambient temperature outside that assembly.
b. Air-Flow – Leave space on the front of the unit for airflow into the cooling fans and some space on top of the
unit for air to exit the unit. Adequate air flow is required for safe operation.
c. Mechanical Loading – The mounting ears were designed for two ears to support one unit. Other
configurations, such as mounting other equipment directly on top of the unit or using only one mounting ear,
could cause a hazardous condition due to uneven or excessive mechanical loading.
NOTE: Use all four mounting screws to properly secure the unit to the rack.
Mounting
Ears
Front
Back
Mounting
Ears
Rack Mounting