27
2.5 Access
Devices
2.5.1 Number of RS-485 Devices
Default value is 0.
This programming sequence sets how many remote RS-485 devices are connected to the 1838
Access Plus system.
1. Press * 0 9 and enter the MASTER CODE. [ * 0 9 _ _ _ _ (beep)]
2. Enter the number of RS-485 devices connected, then press *. Valid numbers are 0 through
6. Entering a 0 in this step will disable RS-485 communication.
[ _ * (beep)]
3. Press 0 # TOGETHER to end. [ 0 # (beeeeeep)]
2.5.2 Additional Relay Off-Line Function
Default value is 0.
This programming sequence sets how the remote RS-485 devices connected to the 1838 Access
Plus will behave if RS-485 communication to the device fails.
Entering a 1 in step 2 sets the remote device to grant access to any five-digit card, transmitter or
access code, whether it has been programmed into the system or not, if RS-485 communication fails.
Entering a 0 in step 2 means that access will not be granted at the device if RS-485 communication
fails. In this case, the 1838 Access Plus and any other remote devices may still be operating
normally as along as they have a good RS 485 communication link.
1. Press * 0 7 and enter the MASTER CODE. [ * 0 7 _ _ _ _ (beep)]
2. Enter a 0 or 1, then press *. [_ * (beep)]
3. Press 0 # TOGETHER to end. [ 0 # (beeeeeep)]