Electric Test Pump
Dixon 800.355.1991
Dixon's Portable Electric Hydrostatic Test Pump (E.T.P.)
Features:
• Campbell Hausfeld 110 volt Portable Hydrostatic Electric Pump - Model (ETP)
• 2000 psi maximum test pressure
• 1.3 gpm fill rate (at 60 psi inlet water pressure)
• Quick connect garden hose coupler for water supply line
• 1/2" x 15 ft. Intermediate hose with brass Straight-Thru Quick Coupler x
NPSM swivel connection.
• 1/2" brass Straight-Thru plug on pressure outlet
• 0 – 5000 psi bottom mount liquid filled pressure gauge
• Test caps, test plugs and pressure relief valves available. Consult the current
Dixon Price List (DPL) for part numbers and pricing.
Recommendations
• If an extension cord is needed, the following wire sizes must be used:
25' Cord - not less than 14GA wire
50' Cord - not less than 12GA wire
100' Cord - not less than 10GA wire
Electric damage or personal injury can result from using improperly grounded outlets.
Only a properly grounded 115 Volt outlet accepting three pronged plug should be used.
Serious damage can result from improper or inadequate electric set up. Fuses, wiring
and electrical codes for proper amperage and grounding should be checked.
Make sure that no water / liquid is anywhere that could cause electric shock to the
operator (i.e. on the floor or pump where it could come in contact with electric
connection).