Dixon Valve Pneumatic Test Pump Manual User Manual
Page 2
2
Pneumatic Test Pump
Dixon Valve & Coupling 800.355.1991
Dixon Portable Pneumatic Hydrostatic Test Pump (PTP)
Specifications
• Haskel model 4B-14-D3 Air over hydraulic pump
• pump made of aluminum with hard coated aluminum plunger
• 1500 PSI output pressure at 100 PSI inlet air pressure
• 5.5 GPM fill rate (at 60 PSI inlet water pressure)
• Air Chief ¼" Industrial Series plug quick connect air connection
• quick connect garden hose coupler for water supply line
• ½" x 15' intermediate hose with brass Straight-Thru quick couplers both ends
• ½" brass Straight-Thru plug on pressure outlet
• 0 – 2000 PSI center mount liquid filled pressure gauge
• Test caps, test plugs and pressure relief valves are available; consult your cur-
rent Dixon Price List (DPL) for part numbers and pricing.
Recommendations
• Use a Coalescing Filter. Oil or air tool lubricant will damage the seals of the
pump very quickly. The coalescing filter, installed in front of the supplied modu-
lar air filter / regulator, will prevent oils from entering the air dome of the pump.
Coalescing filters are available from Dixon Valve & Coupling Company. Consult
your current Dixon Price List (DPL) for part numbers and pricing.
• Use a 5 to 10 micron Water Filter. Particulate matter, present in all water sup-
plies, will damage the check valves and hydraulic seals very quickly. These
filters (cartridge type) can be purchased from W.W. Grainger or from other plumb-
ing supply centers.