50 Ton Ram Instruction Manual

1¼" through 4" Standard & Long Flanged Holedall Swaged Couplings using Collar with Jack Screws

customer service

800

355

1991

5

Section 3

Align the flange face with the pusher.
For 4" assemblies, the raised face on the flange will
fit into the recess of the Main Pusher (50T-009).
For 1-1/4" - 3" assemblies ensure the flange face
and the pusher are flush.

Loosen the bolt on the tie down bar holding the die
in place. Move the tie down bar so that it clears the
collar. When this is done, snug the bolt on that tie
down bar.

11b

11a

12

10b

Loosen all of the jackscrews so that they clear the
flange. Loosen the nut on the “T” bolt so that the “T”
bolt moves easily out of its slot. Remove the collar
from between the flange and the ferrule.

Depress and hold the button on the remote until the
top of the ferrule (where welded to stem) is even
(flush) with the top of the die. Release the button.
Return the directional control lever to the
“NEUTRAL” position.

Note: If the gauge reads 10,000 PSI before swaging
is complete, stop. The ferrule or die used for that
hose end may be incorrect. Contact Dixon for
further assistance.