1)

Slide the 51970 Roll - over attachment on to the head of the 51960 Screw - action tool.

2)

With handle of 51970 facing installer, place 51960 in a vise and tighten.

3)

Slide the clamp tail through the slot on the 51970.

4)

Press down on pulling-dog lever and rotate handle to begin tightening.

5)

Tighten clamp to desired tension.

6)

Simultaneously relieve some tension while rolling hose towards cutter.

7)

When clamp buckle engages cutter, pull handle.

Operating Instructions for the 51960 with 51970 Roll-Over Attachment

51960 - INHOUSE0407