Protection function – Acer AL1912 User Manual
Page 27

- 27 -
AC-DC Output Specification
Tolerance
Output
Current
Output Voltage
---
MIN
MAX
Voltage Tolerance
+5Vdc
+5 /-3 %
0.05A
1.5A
4.85~5.25V dc
+15Vinv +35/-5
%
0A
2A
20~14.3Vdc
+5Vaudio
±5%
0A 0.6A
4.75~5.25Vdc
Ripple ---
1%
+5Vdc:50mVp-p
+15Vinv:150mVp-p
Noise
1. Measured at DC
output terminals which
are paralleled with a
10uf Ecap &0.1uf
Ceramic cap.
2.Band width is limited
within 20MHz.
--- 3%
+5Vdc:150mVp-p
+15Vinv:450mVp-p
Dynamic Load Regulation
50~100% or 100~50%
load change of any DC
output @50% duty of
1MHz (min.)
---
±5%
---
Over / Under Shoot
@ Power line on/off
---
±5%
---
*+5Vdc load regulation test: the +15Vinv loading at 2.0A
*+15Vinv load regulation test: the +5Vdc loading at 1.5A
Protection function
1) SCP: Short circuit protection must be acted on both outputs
2) OPP: Should be protected when output power consumption is within 60W ~ 75W
- S240HL (2 pages)
- S242HL (27 pages)
- P226HQV (2 pages)
- P216H (23 pages)
- S212HL (28 pages)
- S211HL (2 pages)
- S211HL (27 pages)
- P186HV (2 pages)
- P186HV (23 pages)
- P196HQV (23 pages)
- P186H (2 pages)
- X163W (23 pages)
- X163W (3 pages)
- V223W (28 pages)
- V233H (26 pages)
- P235H (24 pages)
- P201W (2 pages)
- AL1917X (11 pages)
- 3230 (100 pages)
- AL1713bm (11 pages)
- ADEY (24 pages)
- X233HZ (26 pages)
- X233HZ (3 pages)
- X243HQ (51 pages)
- AL1751 (20 pages)
- AL2021 (130 pages)
- AL1917C (10 pages)
- 41L1500-786-1A (20 pages)
- AL2032 (9 pages)
- X243W (21 pages)
- AL2017 (11 pages)
- 41L1700-786-7A (20 pages)
- AL1917T (16 pages)
- X263W (24 pages)
- AL1703 (9 pages)
- AL1731 (3 pages)
- al200 (19 pages)
- AL1911 (10 pages)
- AF 707 (5 pages)
- AL1712 (10 pages)
- AC 711 (7 pages)
- AL1502 (17 pages)
- AL1932 (10 pages)
- X223W (2 pages)
- X223W (26 pages)