Mallory Ignition Mallory HYFIRE HEI MODULE 699 User Manual
Hyfire hei module, Part no. 699, Installation instructions
HYFIRE HEI MODULE
PART NO. 699
INSTALLATION INSTRUCTIONS
FORM 1561M 10/03
The Mallory HyFire HEI Module is designed to
replace the entire 4 pin GM module and
connector/harness assembly in GM 4, 6 (even-fire),
and 8 cylinder HEI distributors. Only the GM
pickup/stator assembly will remain of the original
triggering system.
For optimum performance, use Mallory High
Performance Coil 29215 in street and racing
applications.
INSTALLING THE MODULE-
1. After removing the cap and rotor assembly,
disconnect the 2 wires from the pickup/stator
assembly, remove the mounting screws, and
remove the GM 4 Pin module, connector/harness
assembly that it plugged into as an assembly.
2. Clean off the pad area of the distributor housing.
Use a surface or contact cleaner that leaves no
residue.
3. Put an even coat of the supplied heat sink
grease across the entire aluminum heat sink of
the module.
4. Place the module into position into place,
inserting the wiring harness into the notch in the
housing and snug the mounting screws down.
This will even out the grease film. Do not tighten
completely yet.
5. Use the supplied 8-32 screw to hold down the
back end of the circuit board. Once this screw
has been started into the threads, tighten the two
module screws down snugly. DO NOT overtighten!
Once these two screws have been tightened, then
tighten the remaining screw at the end of the PC
board.
6. Connect the two wires from the pickup/stator
assembly to the 2 spade terminals on the circuit
board. Note that there are two different terminal
sizes!
7. Select the number of cylinders using the 2 bottom
switches as shown in the diagrams below.
MALLORY IGNITION
www.mrgasket.com
1
4 CYLINDER
6 CYLINDER
8 CYLINDER