beautypg.com

Performance cd ignition system – Mallory Ignition Mallory HYFIRE VII Series Electronic Ignition Controls 667S User Manual

Page 5

background image

HYFIRE

®

VII

S

TOP PANEL CONTROLS

Basic Operation

The top panel has a three-digit LED display, three LED indicators, and three

switches. The switches are used to set the mode and mode values, and the 3

separate LEDs indicate the mode. The four modes are listed below:

RPML LED

Main RPML (normally used as an engine protection RPM limit)

This value is valid as long as another RPM limit has not been selected. The range

is 1000 to 12800 RPM, in 100 RPM steps.

“AUX” LED

Aux RPML2 (normally used as a launching RPM control)

This value, if selected, overrides the main RPML. Range is 1000 to 12800 RPM,

in 100 RPM steps.

“RET” LED

HS RETARD1

This is a high-speed retard function which will retard the engine timing when

selected. The range is 1 to 15 degrees in .1 degree steps.

ALL MODE LEDs BLANK

CYLINDER NUMBER

This function allows you to select the engine cylinder number from 4 to 12 cyl-

inders.

Setting Mode and Values

To adjust one of the modes, press the "MODE" switch until the proper mode LED

is lit (or none are lit, if you're selecting the cylinder mode ), then use the arrow

keys to increase or decrease the value. If you go past one end of the mode range,

the display will start over at the other end. For example, if you continue to

increase the RPML value past 12,800, the display will start over at 1000 RPM.

Start Retard

The HYFIRE

®

VIIS has a feature shared with the HYFIRE

®

VIIC: a built-in

automatic start retard. This automatically retards the engine timing below 500

RPM. The retard increases to 20 degrees at 100 RPM. Below 100 RPM, the

retard is fixed at 30 milliseconds, and above 500 RPM there is no automatic

retard.

Activation Plug

Although the activation plug has 8 contacts, only two are used on the

HYFIRE

®

VIIS: RPML2 for the Aux RPML, and HSRET 1 for the High-Speed

Retard function. If you add the optional HYFIRE

®

VIIC External Control Part No.

674, all other functions except the RPM switch relay contacts are available. The

plug has clamp-type terminals that will accept up to 14 gauge wire (stranded is

preferred, but solid will work). Insert the wire into the clamp, then tighten the

screw to hold the wire in place. The plug also has screws at each end to firmly

fasten to the socket on the HYFIRE

®

VIIS circuit board. Do not overtighten these

screws. Each RPML or Retard function requires 12 volts to activate. Typical

methods are clutch switch, trans brake switch, nitrous solenoid, or similar.

RET2

RET3

DOWN

UP

R

R

PERFORMANCE CD IGNITION SYSTEM

PERFORMANCE CD IGNITION SYSTEM

PART NO. 667S

R

R

MODE

RET1

RPM3

RPM2

RET

AUX

RPML

NC

C

NO

RPM2

*RPM3

RET1

*RET2

*RET3

NOT USED ON HYFIRE

®

VIIS

+12 VOLTS TO ACTIVATE

+12 VOLTS TO ACTIVATE

*Only used when optional

PN674 is connected.

Mallory-Ignition.com

4