UNILITE

®

ELECTRONIC BREAKERLESS CONVERSION KIT

FOR MALLORY POINT DISTRIBUTORS

NOTE: This product is legal in California only for racing vehicles which may never be operated upon a highway.

INSTALLATION INSTRUCTIONS

FORM 1466 (REV. D) 10/03

APPLICATIONS

Part No. 558

Mallory 8 cylinder point distributors
(automotive and marine) which use
a standard stack cap (Part No. 209
or 209D)

Part No. 559

Mallory 8 cylinder point distributors
(automotive and marine) which use
a flat cap (Part No. 221 or 221B)

Part No. 560

Mallory 6 cylinder point distributors
(automotive and marine) which use
a standard stack cap (Part No. 270
or 270B)

Part No. 561

Mallory 6 cylinder point distributors
(automotive and marine) which use a
mini bowl cap (Part No. 226 or 226B)

Part No. 562

Mallory 4 cylinder point distributors
(automotive and marine) which use
a standard stack cap (Part No. 271
or 271B)

Part No. 563

Mallory 4 cylinder point distributors
(automotive and marine) which use a
mini bowl cap (Part No. 225 or 225B)

PARTS INCLUDE IN THIS KIT:

1

UNILITE

®

Plate Assembly

1

Wire Harness

1

Rotor/Shutter Wheel Assembly (PN 559 contains
2 rotor/shutter wheel assemblies)

1

Wire Connector

1

Grommet, 3-Hole (Marine Approved)

2

Pins, Aluminum

1

Thrust Button

WARNING

You must install the UNILITE

®

Conversion Kit

exactly as shown in these instructions. After the
kit is installed—and before you start the engine

check all wiring again. Mis-wiring will cause the
UNILITE

®

Ignition to fail immediately.

INSTALLATION

Step 1
Remove the cap and rotor, then remove the con-
denser. Remove the plastic insulators (see Figure 1).

Step 2
Loosen the 2 nuts that hold the cap clips/brackets in
place (see Figure 1).

NOTE: To loosen the nuts on a marine distributor,
the aluminum pins in the brackets may need to
be cut in two and removed. Replacement pins
are provided.

Step 3
Remove the point plate assembly by lifting it out of
the housing (see Figure 1).

MALLORY IGNITION

www.mrgasket.com

1

IMPORTANT

All kits listed below must be used with an ignition ballast resistor (or loom resistance wire) to prevent
module failure. If your vehicle is not equipped with a ballast resistor or loom resistance wire, Mallory
Ballast Resistor (Part No. 700) may be used. These kits do not work with vacuum advance distributors.

FIGURE 1

Condenser

Insulators

Point Plate

Cap Clip Nuts