8. Select the rev limit using the 6 top switches.

The minimum rpm (with all switches in the "off"
position) is 5,000 rpm. For higher rpm limits, add
the value of the switches in the "on" position to
the base setting of 5,000. See the examples
below.

Note: If your distributor is showing signs of
bushing wear or if there is backlash in the
distributor/cam gear combination, the rev limit
my start 100 to 300 rpm below the rpm that you
have selected.

9. Reinstall the cap and rotor and set the ignition

timing. You may notice a slight timing change
now that you have installed your ACCEL #35373
HEI Module. This is normal. If your change is
substantial, you may have reversed the pick up wires.

5000 RPM

6500 RPM

8700 RPM

All switches in

the “OFF” position

5000 + 0 = 5000 RPM

5000 + 1000 + 400 + 100 = 6500 RPM

5000 + 2000 + 1000 + 400 +
200 + 100 = 8700 RPM