beautypg.com

Magnum Venus Plastech High Volume Pro Gun 60625-1 User Manual

Page 24

background image

High Volume Pro Gun Manual

Rev. 05/2012

Page | 24

Remove Check Valve on International HV Pro Guns

1.

Remove the check valve on the side of the gun block

Or

Remove Catalyst Plug on Domestic HV Pro Guns

1.

Remove the plug (5104-32-1) from the side of the gun block


2.

Check o-ring (O-E-5-125) for damage

Note: This valve serves as a check valve for the catalyst system.

DANGER: If this valve must be replaced, contact Magnum Venus Products. These
valves have undergone specific remanufacture at Magnum Venus Products for use with
the HV Pro Gun™. Using a check valve not obtained directly from Magnum Venus
Products may result in contamination and/or dangerous ignition of the catalyst.

Clean Block Assembly

• Discard o-rings and seals.
• Clean remaining components with solvent and allow to air dry.
• You have now disassembled the gun block.




















This manual is related to the following products: