Connects into the MPG leak signal.

PPVS-1000 TEST PROCEDURES:

Testing and Adjusting PPVS-1000 vacuum setting:

1. Option #1 - connect the INJECT Output

on the control box to the PPVS supply
port using 4 mm tube.

2. Connect the PPVS signal line to the

pneumatic Indicator on the control box.

3. Using the Vacuum Level Control adjust the

vacuum level Up/Down to determine the
vacuum pressure that the valve activates &
deactivates at. The indicator will signal red
when the valve is active.

4. To Adjust/Change the vacuum pressure at

which the valve activates use the 2.5 mm
Allen Key provided. Turn the adjustment
screw Clockwise to switch closer to
atmosphere (nearer to zero) and
Anticlockwise to switch down to -300mb
(higher vacuum pressure).


Option #2 – Test with Unit connected – for
SSB or Innovator units the 4mm pipe may be
left connected as designed and a 6mm pipe
connected between the Leak Signal on top of
the PPVS and the machine’s MPG. The
machine can then be put on re-circulation and
observed to stop when the PPVS signals at
the chosen switch point.

1. Connect the INJECT Output to the PPVS

supply port using 4 mm tube.

2. Then “Tee” the PPVS Leak Signal port

on the top of the PPVS into the MPG
signal using 4 or 6 mm tube.

3. Using the Vacuum Level Control adjust

the vacuum pressure Up/Down. The Unit will stop when the PPVS activates the
leak port.