FRP SystemOne

Gelcoater

relief valve located on the top of the lid. Set flush tank pressure at
50 to 60 psi.

2. Push the flush valve on the side of the gun block to test solvent

flush.

Priming Catalyst to Gun:

1. Tighten the catalyst packing nut ¼ turn.

2. Fill the two gallon catalyst jug ¾ full, purge the air out of the catalyst

feed line by slightly tilting the catalyst jug.

6

Air supply:

1. Use minimum ½” air hose supply to the system. Air requirements, 9

to 10 CFM

2. Open incoming air supply ball valve.

3. Set regulator labeled gun at 90 to 100 psi. Tighten packing nuts on

the gun and trigger the gun 15 to 20 times. Snug packing nuts again
and repeat gun triggering.

Priming Solvent:

1. Open solvent tank lid and fill ¾ full. Install lid on tank and close the

Chapter

3

FRP SystemOne Gelcoater
Operation

Wetting Out Unit