beautypg.com

Magnum Venus Plastech System One FRP 1300-1-1 User Manual

Page 7

background image

FRP SystemOne

Gelcoater

4. Mount catalyst jug bracket.

a. Attach the Catalyst jug bracket to the base of the catalyst pump

slide drive support.

b. Mount the bracket so it extends to the left side of the slide drive

support as you stand facing the end of the slide drive.

5. Mount solvent tank retainer bracket.

a. Attach the tank bracket to the column approximately 2 to 3

inches from the top of the floor mount frame round tube.

b. The bracket should be on the left side of the column as you face

the unit. Position the bracket so the tank will sit on the floor
mount square tubing. Tighten the flush tank bracket bolts to the
column.

c. Remove the solvent tank from the carton and place into bracket.

6. Attach catalyst pump.

a. Mount the Catalyst pump to the slide drive bracket using the

clevis pins and keepers provided.

b. The bottom of the catalyst pump is pinned to the lower leg of the

slide drive bracket.

c. The upper clevis, (piston rod), is pinned to the slide drive using

the forward of the long slot in the slide drive.

d. Hold the clevis pins in place with the wire keepers by placing

them in the holes in the clevis pins.

7. Mount air supply manifold.

a. Clamp manifold assembly to the pump column above the power

cylinder of the resin pump.

b. Regulators and gauges should face to the pump side of the

column.

c. Clamp yoke tight enough so the assembly does not move

around the column.

8. Attach suction wand to gelcoat pump.

a. Check all fittings on the wand assembly to make sure they are

airtight.

b. Attach the wand assembly to the foot valve swivel fitting and

tighten.

4

NOTE

If SystemOne Gelcoater unit is configured with a catalyst
alarm, please refer to the catalyst alarm manual when you
reach this stage of set-up.