9. Make hose connections.

a. Connect the black resin hose from the gun to the outlet fitting on

the resin filter.

b. Connect the catalyst hose from the gun to the outlet of the

catalyst pump assembly.

c. Attach the red air hose from the gun to the fitting on the regulator

labeled gun.

d. Attach the yellow poly flush hose from the gun to the outlet fitting

of the solvent tank.

e. Attach the small red air supply hose from the flush regulator to

the input fitting on the flush tank.

f.

Attach the red air hose from the pump regulator to the power
cylinder or the gelcoat pump.

g. Attach the ground wire from the gun to the electrical grounding

lug on the pump power head.

h. Remove the catalyst poly tubes from the component box. Cut

the ½” inch diameter poly line with the clamps to 26 inches long.
Clamp one end to the outlet of the catalyst jug and the other end
to the inlet of the catalyst pump. Make sure the clamps are
airtight.

i.

Connect the 3/8-inch poly line to the relief valve on the catalyst
relief valve and insert the other end into the hole in the top of the
catalyst jug.

j.

Connect the green hose from side of the gun handle to the blue
valve on air manifold.

10. Mount exhaust muffler to the power head of the gelcoat pump.

a. Remove the exhaust deflector from the power head of the

gelcoat pump, (4 screws). Screw silencer into the pipe threads
of the exhaust port.

5