RA – 121 RACK MOUNT ARCHITECTURAL DIMMER

Revision 0.93

OWNERS MANUAL

09/26/2011

www.lightronics.com

Lightronics Inc.

509 Central Drive Virginia Beach, VA 23454

Tel 757 486 3588











USING THE MENU SYSTEM

The

CONFIG

button steps through the five display

menus. When one of these menus is shown you can
push

ENTER

to access that function. The

CLEAR

button will return the unit to its normal operating
mode and cause the display to show the channel level
bar graph. The

CLEAR

button DOES NOT clear

entered values. The arrow buttons are used to set
menu selections.

SYSTEM MODE

The RA-121 currently uses only the

NORMAL

setting

for system mode.

At the

RA-121

front panel - push

CONFIG

until the

System Setup

appears on the status display.





Push

ENTER

. The System Mode menu will be

shown.



Push

ENTER

. The System Mode Selection menu will

be shown.




Use the and buttons to select the

NORMAL

mode. Push ENTER when finished.

SYSTEM POWER SETUP






In addition to making the correct power connections
for the power source at your installation, the RA-121
must be set up to correctly respond to the power type.

At the RA-121 front panel - push

CONFIG

until the

System Setup

menu appears on the Status display.


Push

ENTER

. Then push

CONFIG

until the System

Power menu appears on the status display.



Push

ENTER

. The display will show the current

power configuration. For example:



Use the and buttons to select a configuration
corresponding to the actual power being supplied to
the RA-121. Push

ENTER

when correct power type is

shown. The available choices are shown below.

RA 3Phas

120/208V 3 Phase Power Source

RA 2Phas

120/240V Single Phase Power Source

OR

2 Phases of 120/208V 3 Phase Source


NOTE: There are several other settings available
in this menu. These other choices do not apply to
the RA-121 dimmer

UNIT ADDRESS ASSIGNMENT

When using a single RA-121 unit in a system, the unit
address MUST BE SET TO

00

. One (and only one)

RA-121 in a multiple unit system must be set to unit
address

00

. Other units should be assigned in a

consecutive order.

Set Dimmer

Operating

Options

SCENE

SETUP

EVENT

SETUP

DMX I/O

SETUP

DIMMER

SETUP

SYSTEM

SETUP

ENTER

ENTER

ENTER

ENTER

ENTER

Create and Edit
Internal Scenes

Set Clock and

Timed Events

Assign DMX

Addresses

Set Individual

Channel

Behavior

D

TOP LEVEL MENUS LAYOUT

MENU
(NEXT)

MENU
(NEXT)

MENU
(NEXT)

MENU
(NEXT)

MENU
(NEXT)

SYSTEM
SETUP

SYSTEM

MODE

SYSMODE
NORMAL

SYSTEM
POWER

SYSTEM

RA 3Phas

CAUTION

TURN OFF ALL CHANNELS AND OPEN ALL

CHANNEL CIRCUIT BREAKERS BEFORE

CHANGING THE INPUT POWER SETUP.

SYSTEM
SETUP