RA – 121 RACK MOUNT ARCHITECTURAL DIMMER

Revision 0.93

OWNERS MANUAL

09/26/2011

www.lightronics.com

Lightronics Inc.

509 Central Drive Virginia Beach, VA 23454

Tel 757 486 3588

MAINTENANCE AND REPAIR







TROUBLESHOOTING

ƒ

To simplify troubleshooting - reset the unit or

provide a known simple set of conditions.

ƒ

Check that the console is powered and that

console channels are correctly patched or set.

ƒ

Check the control cable between the dimmer(s)

and console.

ƒ

Verify the loads and their connections.



OWNER MAINTENANCE

FRONT PANEL FUSES:

The RA-122 has two fuses.

The left fuse is 1 Amp. The right fuse is 1/4 Amp.
Both are 250V, 1.25 x .25 inch, fast acting fuses.
These fuses provide protection for the internal
electronic control circuitry and the fan. They may be
replaced ONLY by fuses of identical type and size.

There are no user serviceable parts inside the unit.

The best way to prolong the life of your unit is to keep
is cool, clean, and dry. It is important that the cooling
intake and exit vent holes are clean and unobstructed.

Service by other than Lightronics authorized agents
may void your warranty.

OPERATING AND MAINTENANCE ASSISTANCE

If service is required, contact the dealer from whom
you purchased the equipment or contact Lightronics,
Service Department, 509 Central Drive, Virginia
Beach, VA 23454 TEL 757 486 3588.

Lightronics recommends that you record the serial
number of your unit for future reference.

SERIAL NUMBER

___________________




RA-121

UNIT

SPECIFICATIONS

CHANNELS/CAPACITY:

12 @ 1200 Watts each

POWER REQUIREMENTS:

120/208VAC three phase,40 Amps each line

OR

120/240VAC single phase, 60 Amps each line

POWER DEVICES:

40 Amp triacs

POWER CONNECTOR:

Terminal Block

CHANNEL OUTPUT: Edison Plug
External

Terminal

Strip

Patch

Panel

Socapex

CIRCUIT BREAKERS: 10 Amp fast acting

MINIMUM LOAD:

15 Watts

CURVE:

Modified

square

law

FILTER RISE TIME:

350 usec. minimum

OUTPUT FUNCTION: DIMMER or RELAY

selectable

CONTROL INPUT:

DMX-512 U.S.I.T.T. standard

FRONT PANEL:

8 char. x 2 line LCD display

REMOTE NETWORK: RS-485, 62.5 Kbaud,

bidirectional 9 bit network

LOCAL PRESETS:

100 scenes standard,

expandable

to

255

scenes

CLOSURE INPUT:

8 inputs for single, dual

button,

or

combine

stations

REMOTE STATIONS: Total of 32 remote stations
with

unique

system

addresses

SLAVE UNITS:

Up to 31 additional units may

be

added

SIZE :

3.5"H x 19"W x 13"D

WEIGHT:

27

pounds



WARNING

MAKE CERTAIN POWER IS REMOVED

FROM THE FEED CIRCUITS