MAINTENANCE AND REPAIR
TROUBLESHOOTING
To simplify troubleshooting - reset the unit or
provide a known simple set of conditions.
Check that the console is powered and that
console channels are correctly patched or set.
Check the control cable between the dimmer(s)
and console.
Verify the loads and their connections.
OWNER MAINTENANCE
FRONT PANEL FUSES:
The RA-122 has two fuses.
The left fuse is 1 Amp. The right fuse is 1/4 Amp.
Both are 250V, 1.25 x .25 inch, fast acting fuses.
These fuses provide protection for the internal
electronic control circuitry and the fan. They may be
replaced ONLY by fuses of identical type and size.
There are no user serviceable parts inside the unit.
The best way to prolong the life of your unit is to keep
is cool, clean, and dry. It is important that the cooling
intake and exit vent holes are clean and unobstructed.
Service by other than Lightronics authorized agents
may void your warranty.
OPERATING AND MAINTENANCE ASSISTANCE
If service is required, contact the dealer from whom
you purchased the equipment or contact Lightronics,
Service Department, 509 Central Drive, Virginia
Beach, VA 23454 TEL 757 486 3588.
Lightronics recommends that you record the serial
number of your unit for future reference.
SERIAL NUMBER
___________________
RA-121
UNIT
SPECIFICATIONS
CHANNELS/CAPACITY:
12 @ 1200 Watts each
POWER REQUIREMENTS:
120/208VAC three phase,40 Amps each line
OR
120/240VAC single phase, 60 Amps each line
POWER DEVICES:
40 Amp triacs
POWER CONNECTOR:
Terminal Block
CHANNEL OUTPUT: Edison Plug
External
Terminal
Strip
Patch
Panel
Socapex
CIRCUIT BREAKERS: 10 Amp fast acting
MINIMUM LOAD:
15 Watts
CURVE:
Modified
square
law
FILTER RISE TIME:
350 usec. minimum
OUTPUT FUNCTION: DIMMER or RELAY
selectable
CONTROL INPUT:
DMX-512 U.S.I.T.T. standard
FRONT PANEL:
8 char. x 2 line LCD display
REMOTE NETWORK: RS-485, 62.5 Kbaud,
bidirectional 9 bit network
LOCAL PRESETS:
100 scenes standard,
expandable
to
255
scenes
CLOSURE INPUT:
8 inputs for single, dual
button,
or
combine
stations
REMOTE STATIONS: Total of 32 remote stations
with
unique
system
addresses
SLAVE UNITS:
Up to 31 additional units may
be
added
SIZE :
3.5"H x 19"W x 13"D
WEIGHT:
27
pounds
WARNING