Alto-Shaam ECOSMART HFT2SYS-400 User Manual

Page 11

background image

HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 9 .

e L e C t R i C A L C O N N e C t i O N

i N s t A L L A t i O N

The appliance must be installed by a qualified

service technician. The oven must be properly

grounded in accordance with the National

Electrical Code and applicable local codes.

Plug the unit into a properly grounded receptacle

ONLY, positioning the unit so that the plug is

easily accessible in case of an emergency. Arcing

will occur when connecting or disconnecting the

unit unless all controls are in the “

off

” position.

Proper receptacle or outlet configuration or

permanent wiring for this unit must be installed

by a licensed electrician in accordance with

applicable local electrical codes.

REGARDING INTERNATIONAL

STANDARD UNITS:
If the unit is not equipped with flexible cord with

plug, an all-pole country approved disconnection

device which has a contact separation of at least

3mm in all poles must be incorporated in the fixed

wiring for disconnection. When using a cord

without a plug, the green/yellow conductor shall

be connected to the terminal which is marked with

the ground symbol. If a plug is used, the socket

outlet must be easily accessible. If the power cord

needs replacement, use a similar one obtained

from the distributor.

D A N G e R

to avoid electrical shock, this
appliance mUSt be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the national electrical Code anSi/
nFpa no. 70. in Canada, all electrical
connections are to be made in
accordance with CSa C22.1, Canadian
electrical Code part 1 or local codes.

D A N G e R

eleCtRiCal COnneCtiOnS mUSt
be made bY a QUaliFied SeRviCe
teCHniCian in aCCORdanCe WitH
appliCable eleCtRiCal COdeS.

D A N G e R

enSURe pOWeR SOURCe
matCHeS vOltage Stamped
On applianCe nameplate.

Wire diagrams are included in the literature

package supplied with the unit .

For CE approved units: To prevent an electrical

shock hazard between the appliance and other

appliances or metal parts in close vicinity, an

equalization-bonding stud is provided. An

equalization bonding lead must be connected to

this stud and the other appliances / metal parts

to provide sufficient protection against potential

difference. The terminal is marked

with the following symbol.

eLeCtRiCAL - HFt2-300

voltage

phase

cycle

/

hz

amps

kW

corD

&

plug

208-240

(

agcy

)

1

60

13.6 3.3

NEMA 6-15P

at 208

1

60

11.8 2.5

15A - 250V Plug

at 240

1

60

13.6 3.3

230

1

50 13.0 3.0

cee

7/7,

220-230

v

plug

eLeCtRiCAL - HFt2-400

voltage

phase

cycle

/

hz

amps

kW

corD

&

plug

208-240

(

agcy

)

1

60

13.7 3.3

NEMA 6-20P

at 208

1

60

11.9 2.5

20A - 250V Plug

at 240

1

60

13.7 3.3

230

1

50 13.1 3.0

cee

7/7,

220-230

v

plug

eLeCtRiCAL - HFt2-500

voltage

phase

cycle

/

hz

amps

kW

corD

&

plug

208-240

(

agcy

)

1

60

15.7 3.8

NEMA 6-20P

at 208

1

60

13.6 2.8

20A - 250V Plug

at 240

1

60

15.7 3.8

230

1

50 15.0 3.5

cee

7/7,

220-230

v

plug