Tdec, Programming flowchart (continued) – Liquid Controls IT300N User Manual

Page 11

background image

9

PROGRAMMING FLOWCHART

(continued)

Press the

key to step the totalizer decimal to the desired location.

Press the E key to enter the displayed decimal location.

Press the M key to skip and keep the existing location

Press the key to step to the desired totalizer descriptor.

Press the E key to enter the displayed descriptor.

Press the M key to skip and keep the existing descriptor.

NOTE: When option "D" (rate per day) is ordered; selections are:

GAL, BBL, MCF, M3, "blank"

Press the key to step to the desired scale setting.

Press the E key to enter the displayed scale setting.

Press the M key to skip and keep the existing setting.

NOTE: When option "D" (rate per day) is ordered; selections are:

min, sec, days

Press the

key to step the ratemeter decimal to the desired location.

Press the E key to enter the displayed decimal location.

Press the M key to skip and keep the existing location

Press the key to increment each individual digit of the delay.
Press the

key to advance to the next digit.

Press the E key to enter the displayed value.

Press the M key to skip and keep the existing value.

Press the key to increment each individual digit of the out low setting (4mA

value). This will only display on units with Analog Output.

Press the

key to advance to the next digit.

Press the E key to enter the displayed value.

Press the M key to skip and keep the existing value.

Press the key to increment each individual digit of the out high setting

(20mA value). This will only display on units with Analog Out-

put.

Press the

key to advance to the next digit.

Press the E key to enter the displayed value.

Press the M key to skip and keep the existing value.

Press the key to step to the desired pulse scale divider for the pulse

output.

Press the E key to enter the displayed pulse scale divider.

Press the M key to skip and keep the existing pulse scale value.

Press the key to step to the desired pulse width for the pulse output.

Press the E key to enter the displayed pulse width.

Press the M key to skip and keep the existing pulse width.

This will not display if Pulse Out is turned OFF.

Press the key to increment each individual digit of the "nor" factor.

Press the E key to enter the displayed value.

Press the M key to skip and keep the existing value.

Press the key to step to the desired lock setting.

Press the E key to enter the displayed lock setting.

Press the M key to skip and keep the existing setting.

Press the key to increment each individual digit of the lock code.
Press the

key to advance to the next digit.

Press the E key to enter the displayed value.

Press the M key to skip and keep the existing value.

TDEC

12345678

ToT DESC

SEC

r SCALE

TOTAL DECIMAL

SCALE

(ratemeter)

SEC

NNIN

HRS

(

Days)

GAL

LIT

FT3

M3

"blank"

(BBL, MCF)

1234

R DECLoC

E

M

E

M

E

M

E

M

0.1

delay

0000

oUT Lo

99999

oUT HI

D 1

Pul scale

OUT LOW

(4mA)

OUT HIGH

(20mA)

PULSE

SCALER

(divider)

D 1

D 1

D 10

D 10

D100

D100

oFF

oFF

0.1 to 99.9

E

M

E

M

E

M

E

M

.5

.5

p uuidth

E

M

.5
.25
.125
.0625

PULSE

WIDTH

(seconds)

1

nor

NORMALIZATION

NORMALIZA

NORMALIZA

E

M

Continued From Previous Page

RUN MODE

0000

loc code

LOCK

CODE

E

M

yes

loC UnIt

TURN LOCK

ON or OFF

yes

no

E

M

TOTAL

DESCRIPTOR

RATE

RA

RA

DECIMAL

LOCATION

LOCA

LOCA

DELAY

DELA

DELA

(Dampening)