background image

Sponsler, Inc.

IT150N Remote Totalizer

pg

3

DOC# MN-150N-B


SPECIFICATIONS

TEMPERATURE:

Operating -40 to 85

°C

Storage -65 to 125

°C

INPUT VOLTAGE:

Internal AA Lithium Battery
Battery Operating Life – 4 years

INPUT SIGNAL:

Frequency 0-2500 Hz
Amplitude 25 mV – 36 V sine or square wave
Sensitivity field adjustable
Impedance 10K

DISPLAY:

LCD, 8 Digit .3” Characters
Totalizer – 8 Digit
Totalizer Reset Externally Initiated
Input factoring .00000001 – 1.9999 allows totalization in any
engineering unit

OUTPUT

Factored pulse output via Open Drain @ 1A

ACCURACY:

Totalizer +/- 1 Count

FEATURES:

Mounts directly on flowmeter
Display Reset Externally Initiated

ENCLOSURE:

FM Approved, C.S.A. Certified
Class I Groups B, C, D
Class II Groups E, F, G
Nema 4
Weight 2.5 lbs.