Formulas for computing gear plate ratios, Examples – Liquid Controls Gear Plate Selection Guide User Manual
Page 7

7
Examples
Formulas for Computing Gear Plate Ratios
Example 1: Find a gear plate ratio for 7.50 pounds per
gallon.
Meter Model: ------------- M7-A
Unit of Measure: -------- pounds per gallon
Packing Gland Ratio: -- 2:1
Units per Gallons: ------ 7.50
Adjuster Ratio: ---------- 3.997
Nb x Rc
Dn
Pg x W x Ra
Dr
= R1
R2 =
5.555 x 10
2 x 7.50 x 3.997
= R1 = .9265
61
57
Dn
Dr
Dn
57
Dr
61
R2 =
=
= .9344
∆R =
=
= .85%
100 (R1-R2)
R1
100 (.9265 - .9344)
.9265
Example 2: Find a gear plate ratio for Imperial Gallons
at 2% correction.
Meter Model: ------------- M7-A
Unit of Measure: -------- whole imperial gallons
Correction Factor ------- (2%) .98
Packing Gland Ratio: -- 2:1
Units per Gallons: ------ .83267 Imperial Gallons per US
Gallon
Adjuster Ratio: ---------- 3.997
Nb x Rc x .98
Dn
Pg x W x Ra
Dr
= R1
R2 =
5.555 x 10 x .98
2 x .83267 x 3.997
= R1 = 8.1785
Dn
Dn
Dn
Dr
Dr
Dr
R2 =
x
x
60
67
75
30
41
30
R2 =
x
x
= 8.1707
∆R =
=
= .095%
100 (R1-R2)
R1
100 (8.1785-8.1707)
8.1785
Dn
Dr
41
67
Dn
Dr
30
60
Dn
Dr
30
75
- MS Meters (40 pages)
- MA4 Meter (32 pages)
- M-MA Meters (28 pages)
- HMS3700 & HMS3770 Insertion Sensors LC Mag Insertion (8 pages)
- HMS501, HMS600, HMS1000, HMS2400, HMS2500, and HMS5000 LC Mag IOM (8 pages)
- CIM100 (16 pages)
- Rate of Flow (4 pages)
- HML4-F1 - LCMag (40 pages)
- LCRII Install E3650-E3651 Series (40 pages)
- LCR-II Setup & Operation (60 pages)
- LCRII Menu Map (2 pages)
- LCR-II - Quick Reference (2 pages)
- LCR Install (24 pages)
- LCR Setup & Operation (60 pages)
- LCR 600 Install (36 pages)
- LCR600 Wiring Schematic (1 page)
- LCR 600 Setup & Op (68 pages)
- LCR 600 - Quick Reference (2 pages)
- FlightConnect 600 (52 pages)
- FlightConnect 600 QR (2 pages)
- LCR-II Installation E3655-E3656 (36 pages)
- LCRII E3651-E3656 Wiring Schematic (1 page)
- DMS Installation (20 pages)
- DMS Setup (84 pages)
- DMS Delivery (52 pages)
- DMS i1000 Quick Reference - DMS Delivery (2 pages)
- DMS Office (52 pages)
- DMS i1000 EZConnect Operators (36 pages)
- DMS i1000 Quick Reference - EZConnect (2 pages)
- EZConnect Office (44 pages)
- FlightConnect Office (36 pages)
- FlightConnect Setup Guide (8 pages)
- DB Manager (20 pages)
- POD (16 pages)
- Dual Meter Multiplexer (8 pages)
- Differential Pressure Transducer (12 pages)
- XL LED Display E1615_E1616_E1617_E1618 (20 pages)
- SCAMP (20 pages)
- WinHost Operation (44 pages)
- SP714-S2i (12 pages)
- HML110 IOM (31 pages)
- HML210 IOM - LCMag (44 pages)
- Sponsler T675 - Cryogenic System Register (54 pages)
- Sponsler IT400 Electronic Register (40 pages)