16. INPUT SIGNAL FILTERING
A moving average filter is selectable in software to process the internal digital readings, which 
are taken at 60/sec with 60 Hz power and 50/sec with 50 Hz power. Eight settings are selectable 
with t equivalent RC time constants from 0.08 sec to 9.6 sec. The longer time constants 
provide superior noise filtering at the expense of fast response time. 
Adaptive moving average filtering allows the transmitter to respond rapidly to actual changes 
in signal while filtering out normal noise. An adaptive filter threshold causes the moving 
average filter to be reset to the latest reading when the accumulated difference between 
individual readings and the filtered reading exceeds that threshold. The accumulated difference 
is also reset to zero when the latest reading has a different polarity than the filtered reading. The 
adaptive filter threshold can be selected as low or high. Low is normally selected. High should 
be selected if the signal has large transients. 
17. TRANSMITTER CALIBRATION
All input ranges are calibrated at the factory using NIST certified calibration equipment, and 
the calibration constants are stored digitally in EEPROM on the signal conditioner board. This 
allows signal ranges and signal conditioner boards to be changed without recalibration. 
Calibration constants for analog outputs are stored in EEPROM on the main board. 
If recalibration is required, a transmitter may be returned to the factory or to an authorized 
distributor. Easy calibration of DC, AC and load cell signal conditioner ranges is also possible 
with Instrument Setup software, as described in Section 7. Advanced calibration software is 
available from the factory. 