9. DC SIGNAL CONDITIONER BOARD JUMPER SETTINGS

Five voltage and four current ranges are jumper selectable. These also have to be selected in
Instrument Setup software.

Board Revision N


Board Revision P


Voltage Ranges

E1

E2

E3

±200.00 mV
±2.0000 V
±20.000 V
±200.00 V
±600.00 V

A
A
B
B
B

f
f

h
h
g

b
a
b
a
a

Current Ranges

E1

E2

E3

±2.0000 mA
±20.000 mA
±200.00 mA
±5.000 A

A
A
A
A

e, h
d, h

c, h

a, b, h

b
b
b
b

E1

a

E2

b

E3

h

a

g

e

d

c

b

f

B

A

Voltage Ranges Jumpers

FS Input

E1

E2

±200.00 mV
±2.0000 V
±20.000 V
±200.00 V
±300V (UL)
±600V (not UL)

A
B
B
B
B
B

f

k

j

h
g
g

Current Ranges Jumpers

FS Input

E1

E2

±2.0000 mA
±20.000 mA
±200.00 mA
±5.000 A

A
A
A
A

e, g
d, g

c, g

a, b, g