beautypg.com

Switch examples – Impulse 2403 User Manual

Page 9

background image

Configuration

Sealevel Systems SeaPORT+4 Page

6

Switch Examples

Figure 2: RS422/485 Interface Configuration


485

Mode Selection

OFF : 422 Mode

The transmitter lines TX+ and TX- are always driven

ON :

485 Mode
The transmitter lines TX+ and TX- are switched to high
impedance when the device is not actively transmitting data

NE

485 option, OFF for 422
OFF : The receiver is always enabled. In a two-wire setup the

receiver will echo back all transmitted data.

ON :

The receiver is disabled when the transmitter is enabled. In a
two-wire setup the receiver will not echo back transmitted
data.

Note: Switch positions 1 and 2 are for port 1 and switch positions 3 and 4 for
port 2 on SW3. Switch positions 1 and 2 are for port 3 and switch positions 3
and 4 for port 4 on SW1.

ON

12

3
4

OF
F

ON

12

3
4

OF
F

485 3
NE 3
485 4
NE 4

485 1
NE 1
485 2
NE 2

SW1

SW3