Dsca, High performance signal conditioners, Dsca specifications – Impulse DSCA49 User Manual
Page 2: Ordering information
High Performance Signal Conditioners
DSCA
Visit our website www.dataforth.com
157
DSCA
Specifications
Module
Typical at T
A
=+25°C and +24V supply voltage
DSCA49-04, -05, -06
Output Range
0 to +10V or -10 to +10V
Over Range Capability
5%
Output Drive
±50mA max.
Output Resistance
0.5
Ω
Output Current Limit
75mA
Output Protection
Continuous
240Vrms max
Transient
ANSI/IEEE C37.90.1
Input Range
0V to +10V or -10V to +10V
Input Resistance
Normal
50M
Ω
Power Off
65k
Ω
Overload
65k
Ω
Input Protection
Continuous
±35V max
Transient
ANSI/IEEE C37.90.1
CMV, Output to Input, Output to Power
Continuous
1500Vrms max
Transient
ANSI/IEEE C37.90.1
CMV, Input to Power
Continuous
50VDC max
CMR (50Hz or 60Hz)
110dB
Accuracy
(1)
±0.05% Span
Nonlinearity
±0.02% Span
Adjustability
±5% Zero and Span
Stability
Zero
±20ppm/°C
Span
±40ppm/°C
Output Noise, 100kHz Bandwidth
2mVrms
Bandwidth, 3dB
1kHz
NMR
100dB/Decade Above 1kHz
Response Time, 90% Span
425µs
Power Supply
Voltage
19 to 29VDC
Current
80mA
Sensitivity
±0.0003%/%
Protection
Reverse Polarity
Continuous
Transient
ANSI/IEEE C37.90.1
Environmental
Operating Temp. Range
40°C to +80°C
ATEX Group II, Category 3
20°C to +40°C
Storage Temp. Range
40°C to +80°C
Relative Humidity
0 to 95% Noncondensing
Emissions EN61000-6-4
ISM, Group 1
Radiated, Conducted
Class A
Immunity EN61000-6-2
ISM, Group 1
RF
Performance A ±0.05% Span Error
ESD, EFT, Surge, Voltage Dips
Performance B
Mechanical Dimensions
2.95" x 0.89" x 4.13
(h)(w)(d)
(75mm x 22.5mm x 105mm)
Mounting
DIN EN 50022 -35x7.5
Ordering Information
DSCA49-04
0V to +10V
-10V to +10V
DSCA49-05
-10V to +10V
-10V to +10V
DSCA49-06
-10V to +10V
0V to +10V
NOTES:
(1) Includes nonlinearity, hysteresis and repeatability.
Model
Input Range
Output Range
Installation Notes:
1.) This Equipment is Suitable for Use in Class I, Division 2, Groups A, B, C, D, or Non-Hazardous Locations Only.
2.) Warning - Explosion Hazard - Substitution of Components May Impair Suitability for Class I, Division 2.
3.) Warning - Explosion Hazard - Do Not Disconnect Equipment Unless Power Has Been Switched Off or The
Area is Known to be Non-Hazardous.