Scm5b, Isolated analog signal conditioning products, Scm5b specifications – Impulse SCM5B33 User Manual
Page 2: Ordering information
Visit our website www.dataforth.com
11
Isolated Analog Signal Conditioning Products
SCM5B
SCM5B
Specifications
Typical at T
A
=+25°C and +5V power
Model
Input (rms)
Output (DC)
Ordering Information
Module
SCM5B33
Input
Signal Range
100mV to 300Vrms, 0 to 5Arms
Standard Frequency Range
45Hz to 1000Hz
Extended Frequency Range
1kHz to 20kHz
Impedance
1 M
Ω
±1% shunted by 100pF (-01 thru -05),
0.10
Ω
(-06), 0.025
Ω
(-07)
Coupling
AC
Protection
(1)
Continuous (-01 thru -05)
300Vrms
Continuous (-06 thru -07)
10Arms
Transient (-01 thru -05)
ANSI/IEEE C37.90.1
Transient (-06 thru -07)
See note 2
Output
Signal Range
0-5V or 0-10V or 0-1mA or 0-20mA or 4-20mA
Current Limit
1.4mA (0-1mA models), 30mA (0/4-20mA models),
8mA (0-5, 0-10V models)
Voltage Limit
±18V (0-5, 0-10V models)
Resistance
50
Ω
(0-5, 0-10V models)
Protection
Continuous Short to Ground
Ripple and Noise (100kHz)
0.025% Span rms
Accuracy
(3)(4)
Sinusoid
50/60 Hz
±0.25% Span
45Hz to 1kHz
±0.25% Reading Additional Factor
1kHz to 20kHz
±0.75% Reading Additional Factor
Non-Sinusoid
Crest Factor = 1 to 2
±0.05% Reading Additional Error
Crest Factor = 2 to 3
±0.15% Reading Additional Error
Crest Factor = 3 to 4
±0.30% Reading Additional Error
Crest Factor = 4 to 5
±0.40% Reading Additional Error
Vs. Temperature
±100ppm/°C
Isolation (Common Mode)
Input to Output, Input to Power
Continuous
1500Vrms max
Transient
ANSI/IEEE C37.90.1
Output to Power
Continuous
50VDC max
Rejection (50-60Hz Common Mode)
100dB
Response Time (0 to 99%)
<400ms
Output Enable Control
Selection Time
6.0µS at C
LOAD
= 0 to 2000pF
Voltage
Max Logic 0
+0.8V
Min/Max Logic 1
+2.4V/+36V
Current 0,1
0.5µA
Loop Voltage
+4.2VDC min, +26VDC max, -40°C to +85°C
Load Resistance (maximum)
(Loop Voltage - 4.2) / (Loop Current)
Supply Voltage
+5VDC ±5%
Current
120mA
Sensitivity
±200ppm/%
Environmental
Operating Temp. Range
-40°C to +85°C
ATEX Group II, Category 3
-20°C to +40°C
Storage Temp. Range
-40°C to +85°C
Relative Humidity
0 to 95% Noncondensing
Emissions EN61000-6-4
ISM, Group 1
Radiated, Conducted
Class A
Immunity EN61000-6-2
ISM, Group 1
RF
Performance A ±0.5% Span Error
ESD, EFT, Surge, Voltage Dips
Performance B
Dimensions (h)(w)(d)
2.28" x 2.26" x 0.60" (58mm x 57mm x 15mm)
NOTES:
(1) SCM5B33 and SCMPB01, 02, 03, 04, 05, 06, 07, XEV rating only. Backpanels obtained from other sources may have lower ratings.
(2) For 1 to 25 seconds the max allowable transient current rating is
√
2500 / (event time). For less than 1 second,
ANSI/IEEE C-37.90.1 applies with a 0.05
Ω
load. For greater than 25 seconds, the 10A rms continuous rating applies.
SCM5B33-01
0-100mV
0-5V
SCM5B33-02
0-1V
0-5V
SCM5B33-03
0-10V
0-5V
SCM5B33-04
0-150V
0-5V
SCM5B33-05
0-300V
0-5V
SCM5B33-06
0-1A
0-5V
SCM5B33-07
0-5A
0-5V
SCM5B33-01B
0-100mV
0-1mA
SCM5B33-02B
0-1V
0-1mA
SCM5B33-03B
0-10V
0-1mA
SCM5B33-04B
0-150V
0-1mA
SCM5B33-05B
0-300V
0-1mA
SCM5B33-06B
0-1A
0-1mA
SCM5B33-07B
0-5A
0-1mA
SCM5B33-01C
0-100mV
4-20mA
SCM5B33-02C
0-1V
4-20mA
SCM5B33-03C
0-10V
4-20mA
SCM5B33-04C
0-150V
4-20mA
SCM5B33-05C
0-300V
4-20mA
SCM5B33-06C
0-1A
4-20mA
SCM5B33-07C
0-5A
4-20mA
SCM5B33-01D
0-100mV
0-10V
SCM5B33-02D
0-1V
0-10V
SCM5B33-03D
0-10V
0-10V
SCM5B33-04D
0-150V
0-10V
SCM5B33-05D
0-300V
0-10V
SCM5B33-06D
0-1A
0-10V
SCM5B33-07D
0-5A
0-10V
SCM5B33-01E
0-100mV
0-20mA
SCM5B33-02E
0-1V
0-20mA
SCM5B33-03E
0-10V
0-20mA
SCM5B33-04E
0-150V
0-20mA
SCM5B33-05E
0-300V
0-20mA
SCM5B33-06E
0-1A
0-20mA
SCM5B33-07E
0-5A
0-20mA
Modules can be ordered with other input/output ranges. Consult factory
for ordering details and specifications.
3. 0V to +5V
NONE
SCM5B33-01
4. 0V to +10V
D
SCM5B33-01D
5. 4mA to 20mA
C
SCM5B33-01C
6. 0mA to 20mA
E
SCM5B33-01E
7. 0mA to 1mA
B
SCM5B33-01B
Output Range Part No. Suffix Example
Output Ranges Available
(3) At standard 60Hz factory calibration. Consult factory for
calibration at other frequencies.
(4) For 10-100% rated span. Add 0.25% accuracy error (-02 thru -07) or
1.00% accuracy error (-01) for 0-10% Span measurements. Accuracy
includes nonlinearity, hysteresis and repeatability but not source or
external shunt inaccuracy (if used).