Setting the rs-232/422 dip switch – AMX AXlink Bus Controllers AXB-232++ User Manual
Page 9

Installation and Wiring
5
AXB-232++ RS-232/422/485 Interface
Setting the RS-232/422 DIP switch
Set the stop bits, data bits, parity, and baud rate on the RS-232/422 DIP switch, located on the front
panel (see FIG. 1 on page 1). The AXB-232++ supports the following asynchronous data
standards:
Stop bits 1 and 2
Data bits 7, 8, and 9
Parity None, Odd, Even, Mark, and Space
Baud rates 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200 and 38,400.
57,600 is achieved by setting the DIP switch to 300 baud, and using the
’
BAUDMED
’ Send_Command (see the Send_Commands section on page 9 for
details).
115,200 is achieved by setting the DIP switch to 300 baud, and using the
’
BAUDHIGH
’ Send_Command (see the Send_Commands section on page 9 for
details).
The table below shows the RS-232/422 DIP switch numbers, functions, and their corresponding
values.
RS-232/422 DIP Switch Settings
Switch
1
2
3
4
5
6
7
8
Function Stop Bits Data Bits
Parity
Baud Rates
Setting
Off
Off
Off
Off
Off
Off
Off
Off
Value
2 bits
7 bits
Unused
300
On
On
On
Off
Off
On
Off
Off
1 bit
8 bits
Unused
600
Off
On
Off
Off
On
Off
Unused
1,200
On
On
Off
On
On
Off
Unused
2,400
Off
Off
On
Off
Off
On
Mark
4,800
On
Off
On
On
Off
On
Even
9,600
Off
On
On
Off
On
On
Odd
19,200
On
On
On
On
On
On
None
38,400
RS232/422
1
2
3
4
5
6
7
8
ON