beautypg.com

Ashly MFA-6000 User Manual

Page 16

background image

Operating Manual - MFA-8000 and MFA-6000 Power Amplifier

16

13.

SPECIFICATIONS

13.1

Output Power

Per channel, both channels driven at 1KHz, < .1%
THD, 120VAC 60Hz

MFA-8000

MFA-6000

8

:

750W

525W

4

:

1200W

800W

2

:

1500W

900W

bridged mono mode

8

:

2400W

1600W

4

:

3000W

1800W (

±

1dB)

per channel from 20Hz to 12KHz*, < .25% THD

8

:

720W

450W

4

:

1100W

700W

13.2

Frequency Response:

±

0.2dB 20Hz - 20KHz

+0/-3dB 8Hz - 100KHz

13.3

Total Harmonic Distortion:

< 0.025%

(720W [450W for MFA-6000] into 8

, 20Hz -

1KHz, increasing to < .25% at 12KHz)

13.4

Output Hum And Noise:

-105 dB from full output
(20Hz - 20KHz unweighted)

13.5

Damping Factor:

> 200 into 8

, 20Hz - 1KHz

13.6

Crosstalk:

-90dB, 20Hz - 1KHz

13.7

Input Sensitivity:

1 Vrms for full output (MFA-8000)
0.81 Vrms for full output (MFA-6000)

13.8

Voltage Gain:

80

×

= 38dB

13.9

Input Impedance:

20K

balanced

13.10

Amplifier Protection:

Fuseless Short-circuit protection, ultrasonic and
RF protection, advanced thermal protection.

13.11

Load Protection:

Turn-on delay relay with level ramp-up, DC fault
protection, ultrasonic limiting, clip limiting.

13.12

Cooling:

Forced air with 2-speed fan.

13.13

Indicators:

11 segment level meters with true clipping top
LED. LIMIT LED indicates when electronic
attenuator is active, THERM LED indicates a
higher than normal operating temperature and
PROTECT LED indicates when output relay is
open.

13.14

Power Requirements:

120 VAC, 50-60 Hz (240VAC available)

Maximum current draw for typical stereo
operation into 4

loads:

MFA-8000

MFA-6000

12 amps

10 amps

Idle current draw:

1.2 Amps

1 Amp

13.15

Size:

19"W x 5.25"H x 16.5"D

13.16

Shipping Weight:

68lbs. (61lbs.)

*Protection circuits will prevent full output
voltage above 12KHz.

This manual is related to the following products: