6.9 Serial COM Interface (RS232)
Pos: 33 /Datentechnik/Schnittstellen/Serielle Schnittstelle COM RS232/Serielle Schnittstelle COM (RS232) für VMT 60xx @ 1\mod_1246373571514_6.doc @ 5876 @
The serial interface is used for digital data transmission. The RS232 interface can be connected by using a
commercially available 9‐pin SUB‐D cable.
Note:
Pin 9 of the serial interface connector can be used for additional switching of a 5V
power supply, e.g. for operating a serial barcode scanner. The COM +5V switch in
the service slot of the device must be put in the ON position in order to use this
function. A subsequent restart of the computer might be required in order to
properly activate this function..
Pin‐Number
Signal‐Name
1
DCD
2
RxD
3
TxD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
RI oder + 5V DC
(max. 1 A)
Note:
This interface is not electrically isolated.