Pushbutton controls, Master / slave installation – Controlled Products Systems Group RAM5000 User Manual
Page 11
RAM 5000 • 5100 • 5200
9
RAMSET
www.ramsetinc.com
Use 3-stranded, shielded wires
(not supplied)
from Master to Slave.
Use jumper
jP7 to jP7
Route low-voltage wires for Master/Slave
in a conduit separate from power.
Conduit
for power
Set Dip Switch (C8) “Slave Mode” to ON for
slave operation.
(RH) Right Hand operation requires Dip Switch
(C7) “Left/Right” to be ON.
Dip Switch “C”
SELECT
ON
OFF
A B COM
A B COM
Three pushbuttons are located under the dip switches for operation of the gate (see Figure 9). The
opening,
stop and closing buttons can be utilized to set limit switches and verify proper system operation when
installing or servicing an operator.
Opening
Pressing this button will cause the gate to open.
Stop
Pressing this button will cause the gate to
stop moving.
Closing
Pressing this button will cause the gate to close.
Reset E.R.D. Board
Push all three pushbuttons for approximately
5 seconds. All three L.E.D.’s should blink.
PUShBUTTON CONTROLS
Figure 10
MASTER / SLAvE INSTALLATION
“Intelligate” Control Board
L.E.D.’s light up when Opening,
Closing or Stopped
Figure 9