beautypg.com

Pushbutton controls, Master / slave installation – Controlled Products Systems Group RAM5000 User Manual

Page 11

background image

RAM 5000 • 5100 • 5200

9

RAMSET

www.ramsetinc.com

Use 3-stranded, shielded wires

(not supplied)

from Master to Slave.

Use jumper

jP7 to jP7

Route low-voltage wires for Master/Slave

in a conduit separate from power.

Conduit

for power

Set Dip Switch (C8) “Slave Mode” to ON for

slave operation.

(RH) Right Hand operation requires Dip Switch

(C7) “Left/Right” to be ON.

Dip Switch “C”

SELECT

ON

OFF

A B COM

A B COM

Three pushbuttons are located under the dip switches for operation of the gate (see Figure 9). The

opening,

stop and closing buttons can be utilized to set limit switches and verify proper system operation when

installing or servicing an operator.
Opening

Pressing this button will cause the gate to open.
Stop

Pressing this button will cause the gate to

stop moving.
Closing

Pressing this button will cause the gate to close.
Reset E.R.D. Board

Push all three pushbuttons for approximately

5 seconds. All three L.E.D.’s should blink.

PUShBUTTON CONTROLS

Figure 10

MASTER / SLAvE INSTALLATION

“Intelligate” Control Board

L.E.D.’s light up when Opening,

Closing or Stopped

Figure 9

This manual is related to the following products: