3 loop detector wiring, Automatic exit loop, Reverse loops – Controlled Products Systems Group 9000-080 User Manual
Page 32: Exit loop port reverse loop port, Doorking plug-in loop detectors

9000-065-F-9-10
30
Automatic Exit
Reverse
4 Ft.
min. to avoid gate
movement inter
ference.
4 Ft.
min. to avoid gate
movement inter
ference.
4 Ft.
min. to avoid
reverse loop inter
ference.
Loop Lead In Wires
Loop Lead In Wires
Reverse
1
ON
2
3
4
1
ON
REVERSE
LOOP
P2
P8
EXIT
LOOP
SELF
TEST
NC
TIME
DELAY
NO
REV SENSE
PRIMARY
REV SENSE
SECONDARY
1
2
3
4
5
6
7
8
9
13
12
11
10
14
15
16
17
18
19
20
2
3
4
5
6
7
8
W
AR
NIN
G
M
OV
ING
GA
TE
CA
N C
AU
SE
Per
son
s are
to k
eep
cle
ar! T
he g
ate
is
cap
able
of
bein
g m
ove
d w
itho
ut p
rio
r w
arn
ing
.
Do
no
t le
t c
hild
ren
op
era
te th
e g
ate
or p
lay
in th
e
gate
are
a.
This
en
tra
nce
is f
or v
ehic
les o
nly
. P
ede
stria
ns
mu
st u
se a
sep
ara
te e
ntra
nce
.
Per
son
s a
re to
rea
d th
e o
wn
er’s
m
anu
al a
nd
safe
ty i
nstr
ucti
ons
.
Fo
r g
ate
op
era
tor
usin
g T
ype
D e
ntra
pm
ent
pro
tec
tio
n, a
n a
uto
ma
tic c
los
ing
de
vice
(su
ch a
s a
tim
er,
loo
p s
ens
or o
r s
im
ilar d
evic
e) s
hall
not
be
em
plo
yed
.
SE
RIO
US
IN
JU
RY
OR
DE
AT
H
CLA
SS
CER
TIF
IED
TO
CA
N/C
SA
C2
2.2
NO
. 2
47
CO
NF
OR
M
S T
O
AN
SI/U
L-3
25
VEH
ICU
LA
R G
ATE
OP
ER
ATO
R
HP
533
82
M
OD
EL
SER
IAL
VO
LTS
PH
AS
E
AM
PS
60 H
z
M
AX
GA
TE L
OA
D
Doo
rKin
g, In
c., I
ngle
wo
od,
CA
2
P8
Exit Loop Port
Reverse Loop Port
9410
9410
Note: Loop detector wiring is shown for
DoorKing plug-in loop detector (P/N 9410-010
Single Channel). If third party loop detectors
are used, refer to the installation instructions
supplied with those detectors for wiring and
separate power instructions.
Automatic Exit Loop
Automatically opens the gate for
exiting vehicles without having to use
a transmitter or keypad. The exit loop
can be placed a minimum of 4 feet
away from the reverse loop or far
enough away from the gate so the
gate has started opening or even
completely opened by the time you
drive up to it (Free exit).
4.3 Loop Detector Wiring
To help protect the operator from accidentally closing on vehicles in the gate’s path, DoorKing highly recommends that loops
and loop detectors be installed. Loops are laid underneath, cut into asphalt or concrete driveways or buried beneath gravel and
earth driveways. A loop detection system will sense a vehicle like a metal detector and send a signal to the gate operator
preventing the gate from automatically opening or closing on a vehicle when it is in the gate’s path. DoorKing recommends that
a licensed installer perform this work.
DoorKing
Plug-in
Loop
Detectors
Single Channel Loop
Single Channel Loop
B
A
Reverse loop
lead-in wires are
twisted approx.
6 twists per foot
and are wired in
series.
A
LOOP 1
B
PVC Conduit
LOOP 1
PVC Conduit
DoorKing offers a free “Loop and Loop-Detectors
Information Manual” PDF located at DoorKing’s
web site for more information.
www.dkaccess.com
4405-010
SW 1
1
ON
2
3
4
5
6
7
8
Exit loop lead-in
wires are twisted
approx. 6 twists
per foot.
Reverse Loops
Reverse loops are placed on each side of the gate to
prevent the gate from closing on a vehicle in the gate’s
path. They will stop or reverse the cycling of the gate
while a vehicle is in or near the gate’s pathway.
Note: SW 1, switch 5 must be set for the
reverse loops. See page 23 for more
information about SW 1, switch 5 ON/OFF
options.