beautypg.com

455 d c, Ontrol, Anel – Controlled Products Systems Group 1042011 User Manual

Page 16: Nstallation, Nstructions, Onnect, Ther, Evices

background image

Page 16

February, 20 09

400 O pe rator And

455 D Control Panel I nst allatio n M anual

NOTE : In order to c om ply with UL 325, two s ets
of FA A C photobeams m us t be ins talled. One s et
s hould be 6 in. outs ide the c los ed gate(s ) and ac t
as a c los ing rev ers ing dev ic e. A nother s et s hould
be 6 in. bey ond the s wing of the gate(s ) and ac t
as an opening rev ers ing dev ic e. The ins taller is
res pons ible for determining the appropriate
m ounting height.

22 23 24 25

1

2

3

4

5

6

7

8

N

L

9

10 11 12 13 14 15 16 17 18 19

115 V A C +/- 10%

or

230 V A C +6/ -10%

50-60 Hz

20 21

-

S TOP

OP E N

OP E N
(1 of 2)

24V

+

FS W

OP

C L

-

FS W

-

-

+

W .LIGHT

24 vdc

3 W

LOCK

E LE CTRIC LOCK

1

2

1

2

3

4

5

1

2

3

4

5

1

2

FS W OP

FS W CL

Other safeties

LA MP

BL

UE

MOTOR 1

C 1

M1

OP

C OM

C L

BL

UE

MOTOR 2

C 2

M2

OP

C OM

C L

Figure 10.

The terminal strip wiring of

the 455 D with photobeams

You cannot check the motor’s direction of rotation
without these circuits (jumpers) or the accessories.

When properly prepared for testing, the LEDS FSWOP,
STOP, and FSWCL should be illuminated (see figure 12
on page 17).

WARNING! Running the operator—even for

testing purposes—without a connected reversing
device is potentially dangerous. Do not place
yourself within the path of the moving gate

during your test.

Disengage the operator(s) with the Manual Release

key (see operator installation manual), and open the
gate by hand about halfway.
Next, engage the operator(s) with the Manual Release

key so that you can check the rotation of the
motor(s).

To activate the operator(s) momentarily short across
terminals labeled “OPEN DEVICES”.

Turn on the main power and send an activating signal
to the operator. The gate leaf (or leaves) should open.
If a gate leaf closes, then you need to turn off the

main power and reverse the connection of the red
and black wires on terminal block for the operator
controlling that leaf. Then you need to recheck the

rotation direction again.

After having completed your test of the motor’s

direction of rotation, replace any test circuits you
installed (between terminals between “PHOTO CL”,
and between “PHOTO OP/CL”) with the proper

reversing devices. The instructions for installing such
accessories follow.

C

ONNECT

O

THER

D

EVICES

WARNING! Turn the main power off before you
make any electrical connections.

P

OWER

S

UPPLY

FOR

A

CCESSORIES

: You can access a 24

VDC output for supplying power to accessories

through terminals (+) and 14 (-) on the pre-wired
terminal block. In most cases, this source can be
used to power 24 VDC accessories.

N

OTE

: The 455 D control panel allows a

maximum accessory load of 800 mA.

R

EVERSING

D

EVICES

: Reversing devices include

photocells, inductive loops, and so forth. All of the
reversing devices should have contacts of the
normally closed (N.C.) type. Where you connect a

device depends on whether you want the device to
operate during opening or during closing.

N

OTE

: UL does not recognize the FAAC system

with loop detectors or safety edges. FAAC
photobeams must be used to comply with UL

325.


To wire photobeams, refer to page 19 (see “PHOTO

OP/CL” for opening photobeams, and “PHOTO C/L”
for closing photobeams). Photobeams must be
connected as shown. See page 19 for the wiring of

inductive loops. If using more than one reversing
device, they must be wired in series.

T

HE

455 D C

ONTROL

P

ANEL

I

NSTALLATION

I

NSTRUCTIONS

This manual is related to the following products: