455 d c, Ontrol, Anel – Controlled Products Systems Group 1042011 User Manual
Page 16: Nstallation, Nstructions, Onnect, Ther, Evices
Page 16
February, 20 09
400 O pe rator And
455 D Control Panel I nst allatio n M anual
NOTE : In order to c om ply with UL 325, two s ets
of FA A C photobeams m us t be ins talled. One s et
s hould be 6 in. outs ide the c los ed gate(s ) and ac t
as a c los ing rev ers ing dev ic e. A nother s et s hould
be 6 in. bey ond the s wing of the gate(s ) and ac t
as an opening rev ers ing dev ic e. The ins taller is
res pons ible for determining the appropriate
m ounting height.
22 23 24 25
1
2
3
4
5
6
7
8
N
L
9
10 11 12 13 14 15 16 17 18 19
115 V A C +/- 10%
or
230 V A C +6/ -10%
50-60 Hz
20 21
-
S TOP
OP E N
OP E N
(1 of 2)
24V
+
FS W
OP
C L
-
FS W
-
-
+
W .LIGHT
24 vdc
3 W
LOCK
E LE CTRIC LOCK
1
2
1
2
3
4
5
1
2
3
4
5
1
2
FS W OP
FS W CL
Other safeties
LA MP
BL
UE
MOTOR 1
C 1
M1
OP
C OM
C L
BL
UE
MOTOR 2
C 2
M2
OP
C OM
C L
Figure 10.
The terminal strip wiring of
the 455 D with photobeams
You cannot check the motor’s direction of rotation
without these circuits (jumpers) or the accessories.
When properly prepared for testing, the LEDS FSWOP,
STOP, and FSWCL should be illuminated (see figure 12
on page 17).
WARNING! Running the operator—even for
testing purposes—without a connected reversing
device is potentially dangerous. Do not place
yourself within the path of the moving gate
during your test.
Disengage the operator(s) with the Manual Release
key (see operator installation manual), and open the
gate by hand about halfway.
Next, engage the operator(s) with the Manual Release
key so that you can check the rotation of the
motor(s).
To activate the operator(s) momentarily short across
terminals labeled “OPEN DEVICES”.
Turn on the main power and send an activating signal
to the operator. The gate leaf (or leaves) should open.
If a gate leaf closes, then you need to turn off the
main power and reverse the connection of the red
and black wires on terminal block for the operator
controlling that leaf. Then you need to recheck the
rotation direction again.
After having completed your test of the motor’s
direction of rotation, replace any test circuits you
installed (between terminals between “PHOTO CL”,
and between “PHOTO OP/CL”) with the proper
reversing devices. The instructions for installing such
accessories follow.
C
ONNECT
O
THER
D
EVICES
WARNING! Turn the main power off before you
make any electrical connections.
P
OWER
S
UPPLY
FOR
A
CCESSORIES
: You can access a 24
VDC output for supplying power to accessories
through terminals (+) and 14 (-) on the pre-wired
terminal block. In most cases, this source can be
used to power 24 VDC accessories.
N
OTE
: The 455 D control panel allows a
maximum accessory load of 800 mA.
R
EVERSING
D
EVICES
: Reversing devices include
photocells, inductive loops, and so forth. All of the
reversing devices should have contacts of the
normally closed (N.C.) type. Where you connect a
device depends on whether you want the device to
operate during opening or during closing.
N
OTE
: UL does not recognize the FAAC system
with loop detectors or safety edges. FAAC
photobeams must be used to comply with UL
325.
To wire photobeams, refer to page 19 (see “PHOTO
OP/CL” for opening photobeams, and “PHOTO C/L”
for closing photobeams). Photobeams must be
connected as shown. See page 19 for the wiring of
inductive loops. If using more than one reversing
device, they must be wired in series.
T
HE
455 D C
ONTROL
P
ANEL
I
NSTALLATION
I
NSTRUCTIONS