beautypg.com

Controlled Products Systems Group PR-112S-A User Manual

Page 4

background image

ENFORCER Stand-Alone Proximity Reader Manual

ENFORCER Stand-Alone Proximity Reader Manual

Key Notch for

Attaching Unit to Base

Screw Mounting Hole

Screw Mounting Hole

Wiring Harness

Access Hole

Nut for Base

Attachment Screw

Sample Installation:

Back

side

Wire Coding:

RED

-- (+) 12VDC

BLACK -- (-) GND
BLUE

-- Egress Input

YELLOW -- N.C. Output
GREEN -- N.O. Output
BROWN -- COM

Relay,
1A@30VDC

Installation Instructions:

1. Unpack the unit and familiarize yourself with the proximity reader and the included parts.
2. Read this manual from front to back. There is a lot of good information here.
3. Test the mounting location for fit.
4. Using a T-10 Torx driver, remove the screw from the bottom of the proximity reader and

separate the outside case from the base.

5. Place the base on the mounting location, and then mark the two mounting holes and the wire-

harness hole.

6. Drill a 1/2" hole for the proximity reader's wire-harness.
7. Permanently screw the base into the mounting location.
8. Run the wires from the power supply, egress button, and door unlock device through the hole

to connect to the wire-harness.

9. Connect the wires to the proximity reader's wire-harness. Solder or crimp the connections,

and carefully insulate them.

10. Reattach the outside case to the base.
11. The preliminary installation is done. Now program the proximity reader.

Beep

B..e..e..p!

Flash
Red!

(User Card)

(Blank Card)

Beep

4

9

RED: 12VDC

12VDC

Power

BROWN: COM (input)

BLACK: Ground

BLUE: Egress Input

EXIT

SALIDA

GREEN: N.O. (output)

Door lock device

(i.e., magnetic lock)

N.O. Egress
switch

YELLOW: N.C. (output)

Entering the Premises – User Card
To enter a protected premise, tap the proximity
reader one time with a user card. The LED turns off
momentarily, the proximity reader sounds one short
beep, and the relay output engages for the
programmed time.

Exiting the Premises –
Egress Button
To exit a protected premise,
press the egress button once.
The LED turns off
momentarily, the proximity
reader sounds one short
beep, and the relay output
engages for the programmed
time.

Accidently Using an Invalid Card
If the proximity reader is tapped using a
blank card, the LED flashes RED and the
proximity reader sounds one long beep.

Operating Instructions: