Wiring diagram, Am3plus – Controlled Products Systems Group AM3PLUS User Manual
Page 6
6
Wiring Diagram
ELECTRIC
DOOR
STRIKE
DOOR
STRIKE
POWER SUPPLY
GATE
OPERATOR
OPEN
GATE
EXIT LOOP
SENSOR
MAGNETIC
DOOR
LOCK
DOOR
LOCK
POWER SUPPLY
DOOR EXIT
REQUEST
BUTTON "A"
DOOR "B"
SENSE
CONTACT
GATE
OPERATOR
OPEN
RS-232
PORT
PHONE
LINE
EARTH
GROUND
STAKE
DOOR EXIT
REQUEST
BUTTON "B"
THIS WIRING EXAMPLE SHOWS:
DOOR ACCESS WITH A DOOR STRIKE ON RELAY CHANNEL "A"
DOOR ACCESS WITH A MAGNETIC LOCK ON RELAY CHANNEL "B"
GATE ACCESS WITH A GATE OPERATOR ON RELAY CHANNEL "C"
TERMINALS 1-30
TERMINALS 31-60
DOOR "A"
SENSE
CONTACT
PBUS
DEVICE
PCLK
DVAL
DAT0
DAT1
GND
PWR
CABINET
TAMPER
SWITCH
16 VAC
20 VA
TRANSFORMER
PBUS
DEVICE
PCLK
DVAL
DAT0
DAT1
GND
PWR
POWER INPUT
12-24 VOLTS
AC OR DC
250 mA MIN.
BACKUP
BATTERY
12V LEAD-ACID
WIEGAND
DEVICE
HOLD
LED1
DAT1
DAT0
GND
PWR
LED2
WIEGAND
DEVICE
HOLD
LED1
DAT1
DAT0
GND
PWR
LED2
12 VOLT
BATTERY
MULTIPLE NETWORK UNITS
REFER TO NETWORK SECTION
FOR WIRING OPTIONS
NETWORK
UNIT
UP TO SIX PBUS
DEVICES CAN BE
USED WITH EACH AM3PLUS
UP TO SIX PBUS
DEVICES CAN BE
USED WITH EACH AM3PLUS
FOR LOCAL COMPUTER CONNECTION
USE LINEAR MODEL A2C
SERIAL COMPUTER CABLE
TO DEDICATED TELEPHONE LINE
(OPTIONAL MODEL ACM-1 MODEM REQUIRED)
TWO WIEGAND
DEVICES CAN BE
USED WITH EACH AM3PLUS
NETWORK
UNIT
NETWORK
UNIT
AM3Plus
CHANNEL D
REQUEST-TO-EXIT
PBUS
POWER
EARTH
TAMPER
CHANNEL B
DOOR SENSE
GND. GND. RTE-A GND. RTE-B RTE-C GND. RTE-D DS-A GND. DS-B DS-C GND. DS-D PWR. GND. DAT1 DAT0 DVAL PCLK T1
T2
N.O.
N.C.
COM.
N.O.
N.C.
COM.
AC-DC AC-DC
N.C.
4
5
6
9
10 11 12 13 14
21 22 23 24 25 26
29 30
1
2
3
7
8
15 16 17 18 19 20
27 28
CHANNEL C
READER B
NETWORK
READER A
PBUS
CHANNEL A
BATTERY
PWR. GND. DAT0 DAT1 LED1 HOLD LED2 PWR. GND. DAT0 DAT1 LED1 HOLD LED2 PWR. GND. DAT1 DAT0 DVAL PCLK NET-A NET-B
N.O.
N.C.
COM.
N.O.
N.C.
COM.
BAT- BAT+
34 35 36
44 45 46 47 48 49 50
57 58
31 32 33
37 38 39 40 41 42 43
51 52 53 54 55 56
59 60
RELAY RATING:
3 AMPS @ 30 VOLTS
AC/DC MAXIMUM