Power, Battery, & Ground Wiring

Power Wiring

NOTE: DO NOT APPLY POWER UNTIL THE INSTALLATION IS

COMPLETE. TURN MASTER POWER SWITCH OFF BEFORE
WIRING.

1. Route two wires between the AM3Plus and the power transformer.

• For power wire runs up to 100 feet, use 18 AWG, 600-volt

insulated wire.

• For power wire runs up to 200 feet, use 16 AWG, 600-volt

insulated wire.

2. Connect the wires to the transformer. Connect the other end of the

wires to the AM3Plus AC1 & AC2 terminals.

Backup Battery

Use of battery backup is optional. It will allow the AM3Plus to operate for
short periods of time without AC power. The door or gate access device
must use some type of battery backup of its own for the entire system to
be functional.
Use a 12-volt gel-cell type battery. Up to a 7-amp/hr. battery will fi t into the
AM3Plus cabinet. Do not use a 6-volt battery.

NOTE: A backup battery is not required to maintain the AM3Plus

clock/calendar and programming memory during power outages.

1. Route two battery leads between the AM3Plus and the backup

battery.

2. Connect the Battery positive to the AM3Plus BAT+ terminal and

the negative to the BAT- terminal.

NOTE: The AM3Plus supplies battery charging current. An

external battery charger is not required to maintain the battery.

Earth Ground

For the best ground, use size 12 gauge solid wire or larger to connect the
to an 8-foot copper ground rod. Locate the ground rod next to the Power
and Telephone company rods and bond the rods together with a new
clamp. Do not disturb the clamps installed by the Power or Telephone
Company. Alternately, connect to a metallic cold water pipe for the earth
ground.

1. Connect the wire from the earth ground to the AM3Plus EARTH

GROUND terminal.

16 VAC

20 VA

TRANSFORMER

POWER

TERMINALS

AC-DC AC-DC

NOTE: THE AM3PLUS
WILL SUPPLY CHARGING
CURRENT FOR THE
BACKUP BATTERY

BAT

BAT

BATTERY

TERMINALS

12 VOLT

BATTERY

EARTH

GROUND

STAKE

EARTH GROUND

TERMINALS