beautypg.com

System diagnostics, Indicators – Controlled Products Systems Group AM3PLUS User Manual

Page 17

background image

17

System Diagnostics

Several indicators on the AM3Plus are for monitoring the system during
operation. When calling for technical assistance, Linear’s Technical
Services Department may ask the installer to use these indicators to
diagnose the system.

Indicators

15 LED indicators are on the AM3Plus. Refer to the fi gure for the location
of each indicator.

POWER lights when AC or DC power is present.
STATUS/PROGRAM DISPLAY shows supervisory and status conditions,

also used for some local programming.

DECODE lights when a credential has been successfully decoded.
VALIDATE lights when a credential is determined to be valid.
ACCESS GRANTED lights when a credential is validated and access is

granted.

PBUS blinks when any PBUS device is successively decoded.
READER “A” fl ashes when Wiegand A device is successively decoded.
READER “B” fl ashes when Wiegand B device is successively decoded.
NETWORK fl ashes in response to network traffi c.
NETWORK HOST ON-LINE lights when the Host PC is connected to the

Master Node.

BACKUP BATTERY LOW lights when backup battery measures low.
RELAY “A” ACTIVE lights when the Channel “A” relay is energized.
RELAY “B” ACTIVE lights when the Channel “B” relay is energized.
RELAY “C” ACTIVE lights when the Channel “C” relay is energized.
RELAY “D” ACTIVE lights when the Channel “D” relay is energized.

POWER

STATUS/PROGRAM

DISPLAY

RELAY "A"

ACTIVE

RELAY "B"

ACTIVE

RELAY "C"

ACTIVE

RELAY "D"

ACTIVE

ACCESS

GRANTED

VALIDATE

DECODE

READER "A"

READER "B"

P-BUS

NETWORK

NETWORK

HOST

ON-LINE

BACKUP

BATTERY

LOW