Solid State Outputs

The two solid state outputs (Output #3 & Output #4) can be
programmed to activate during various conditions. These
outputs can be used to activate indicators or sounders. See
Figure 7 for wiring examples using the solid state outputs.

Beeper Sound Level

The keypad’s beeper can be set to low or high level.

If the keypad’s beeper is too loud for the keypad’s location,
remove jumper JP1 (see Figure 8).

Locking Keypad

After the installation is complete. Lock the keypad using the
keylock (see Figure 9).

REMOVE JUMPER JP1 TO REDUCE
THE SOUND LEVEL OF THE BEEPER

Figure 8. Removing Beeper Jumper

HOOK KEYPAD
ONTO BACKPLATE

USE KEY TO
LOCK KEYPAD

Figure 9. Locking the Keypad Case

OUTPUT #3

OUTPUT #4

COMMON

GROUND

DC
POWER
SOURCE

LED

LED

ELECTRONIC
BEEPER

EXAMPLE 1: OUTPUT #3 LIGHTS AN LED,

OUTPUT #4 LIGHTS AN LED AND SOUNDS A BEEPER

EXAMPLE 2: OUTPUT #3 LIGHTS A LAMP POWERED FROM AN EXTERNAL

SOURCE, OUTPUT #4 TRIGGERS A NORMALLY OPEN ALARM PANEL ZONE

OUTPUT #3

OUTPUT #4

EACH

OUTPUT

100 mA

MAXIMUM

ALARM PANEL

N.O. ZONE

COMMON

END-OF-LINE
RESISTOR

POWER

SOURCE

LOW VOLTAGE

LAMP

EACH

OUTPUT

100 mA

MAXIMUM

1K

Ω @ 12 volts

2K

Ω @ 24 volts

Figure 7. Using the Solid State Outputs

9