beautypg.com

5 hold feature operation – Controlled Products Systems Group 1506-080 User Manual

Page 20

background image

Page 20

3.5

Hold Feature Operation

The relay hold feature allows a set of four-digit entry codes to latch (or hold) a relay indefinitely. Any
four-digit entry code that falls numerically within the hold boundaries will cause relay 1 to activate
indefinitely if no four-digit divide number is programmed. If a four-digit divide number is programmed,
and the divide number is less than the lower hold boundary, then the four-digit codes within the hold
boundary will activate relay 2. If a four-digit divide number is programmed, and the divide number is
greater than the upper hold boundary, then the four-digit codes within the hold boundary will activate
relay 1. If a four-digit divide number is programmed, and it falls between the hold boundaries, then
four-digit entry codes equal to or less than the divide number, but greater than the lower hold
boundary, will activate relay 1 indefinitely. Four-digit entry codes that are greater than the divide
number, but less than the upper hold boundary, will activate relay 2 indefinitely. Five-digit entry codes
are not affected by hold boundaries. To deactivate a relay that is latched, simply re-enter the number
that was used to activate the relay. See sample charts below.

Relay 1

Relay 2

Relay 1
momentarily
activates with
code 2000 or
lower.

Divi

de Numb

er 20

00

Relay 2 momentarily
activates with codes
2001 thru 2009.

Lower Hold

Bound

ary 20

10

Relay 2 latches when
codes 2010 thru 2015
are entered on the
keypad.

Upp

e

r Hold

Bound

ary 20

15

Relay 2
momentarily
activates with
codes 2016 and
higher.

Relay 1

Relay 2

Relay 1
momentarily
activates with
code 2009 or
lower.

Lower Hold

Bound

ary 20

10

Relay 1 latches when
codes 2010 thru 2015
are entered on the
keypad.

Upp

e

r Hold

Bound

ary 20

15

Relay 1 momentarily
activates with codes
2016 thru 2025

Divi

de Numb

er 20

25

Relay 2
momentarily
activates with
code 2026 or
higher.

Relay 1

Relay 2

Relay 1
momentarily
activates with
code 2009 and
lower.

Lower Hold

Bound

ary 20

10

Relay 1 latches when
codes 2010 thru 2012
are entered on
keypad.

Divi

de Numb

er 20

12

Relay 2 latches when
codes 2013 thru 2015
are entered on
keypad.

Upp

e

r Hold

Bound

ary 20

15

Relay 2
momentarily
activates with
code 2016 and
higher.