beautypg.com

6 slave keypad wiring – Controlled Products Systems Group 1506-080 User Manual

Page 13

background image

Page 13

1.6

Slave Keypad Wiring

• Refer to Slave Keypad Instruction Sheet (p/n 1506-066) for instructions on mounting the

1599-010 board onto the 1506-010 circuit board.

• Wire terminals 1-8 on the 1599 board to terminals 1-8 on the 1506-081 slave keypad. Pay

careful attention to the terminal numbers as they can appear backwards (numbered right to
left) when the faceplate is opened.

• Use 22 AWG shielded cable, maximum length 200 feet.
• An additional 2 wires are needed to power the light in the slave keypad. Connect these wires

to terminals 13 and 14 on the 1506 main terminal strip, and to the light wires in the slave
keypad. If DC power is used to power the 1506, you may consider not connecting the slave
light to conserve battery power.

• The slave keypad has no relays! Valid entry codes entered on the slave keypad will activate

the relays in the 1506 keypad.

1599-010 Board

1506-081 Slave Keypad

To Main

Terminals

13 and 14

To Slave

Keypad Light

8-Conductor

22 AWG

Shielded Cable