6 time zone operation – Controlled Products Systems Group 1504-080 User Manual
Page 21
3.6
Time Zone Operation
The entry system has two time zone inputs. By using an external timer or switch, access can be
denied to a group of four-digit entry codes during desired lockout times. Four-digit entry codes that fall
numerically within a time zone boundary will cause a check of the time zone input when the code is
entered. If time zone 1 is activated (switch closure across terminals 3 and 11), four-digit entry codes
that are within the time zone 1 boundaries will be denied access. If time zone 2 is activated (switch
closure across terminals 4 and 11), four-digit entry codes that are within time zone 2 boundaries will
be denied access. Time zone boundaries may overlap each other. Five-digit entry codes are not time
zone restricted.
Time Zone 1
Time Zone 2
Entry codes
1999 and
lower are
not time
zone
restricted.
Lower Bou
n
d
a
ry
2000
U
p
pe
r Bo
un
da
ry
3000
Entry codes
3001 thru
3999 are not
time zone
restricted.
Lower Bou
n
d
a
ry
4000
Entry codes 4000
thru 5000 are
restricted by time
zone 2.
Entry codes 2000
thru 3000 are
restricted by time
zone 1.
U
p
pe
r Bo
un
da
ry
5
0
0
0
Entry
codes
5001 and
higher are
not time
zone
restricted.
Time Zone 1
TZ 2 Lower B
ound
ary
2500
Entry codes
2500 thru
2999 are
restricted bt
TZ 1 and TZ
2.
TZ 1 Upp
er B
ound
ary
3000
Entry codes
3000 thru 3500
are restricted by
TZ 2 only.
TZ 2 Upp
er B
ound
ary
3
5
0
0
Entry codes
1999 and
lower are
not affected
by time
zones.
TZ 1 Lower B
ound
ary
2000
Entry codes
2000 thru 2499
are restricted by
TZ 1 only.
Time Zone 2
Entry
codes
3501 and
higher are
not time
zone
restricted.
1506-065-D-1-09
Page
21