1.6
Secondary Keypad Wiring
1599-010 Board
1506-081 Secondary Keypad
To M
a
in
Te
rm
in
a
ls
13
an
d
1
4
T
o
S
e
c
o
nd
ar
y
Keypa
d L
ight
8-Conductor
22 AWG
Shielded Cable
• Refer to Secondary Keypad Instruction Sheet (p/n 1506-066) for instructions on mounting the
1599-010 board onto the 1506-010 circuit board.
• Wire terminals 1-8 on the 1599 board to terminals 1-8 on the 1506-081 secondary keypad.
Pay careful attention to the terminal numbers as they can appear backwards (numbered right
to left) when the faceplate is opened.
• Use 22 AWG shielded cable, maximum length 200 feet.
• An additional 2 wires are needed to power the light in the secondary keypad. Connect these
wires to terminals 13 and 14 on the 1506 main terminal strip, and to the light wires in the
secondary keypad. If DC power is used to power the 1506, you may consider not connecting
the secondary light to conserve battery power.
• The secondary keypad has no relays! Valid entry codes entered on the secondary keypad
will activate the relays in the 1506 keypad.
1506-065-D-1-09