CCU Hardware Reference
Theory of Operation
CTI Products, Inc.
68-11843-105
7
3.4
Section 3 – Comparator A/B Select
The Comparator A/B Select section has a similar Toggle function as the
Main/Standby function.
There are three external inputs:
•
/Comp Toggle 1
(from Console 1)
•
/Comp Toggle 2
(from Console 2)
•
/Comp Toggle 3
(from Console 3)
There are four logic outputs:
•
/Comp A Select 1
(Normal)
•
/Comp A Select 2
(Normal)
•
/Comp B Select 1
(Inverted)
To Comp B Select Relay
•
/Comp B Select 2
(Inverted)
To Console Input
Note that each output can drive only (1) RYB-8 relay. If you need to control
multiple relays (for TX Audio, Rx Audio & COR), you will have to use one relay
to buffer the coils for the other relays.
3.5
Section 4 – RX Normal / ECS Select
The Rx Normal / ECS Select section has a similar Toggle function as the
Main/Standby function.
There are three external inputs:
•
/Rx Toggle 1 (from Console 1)
•
/Rx Toggle 2 (from Console 2)
•
/Rx Toggle 3 (from Console 3)
There are four logic outputs:
•
/Rx Normal Select 1
(Normal)
•
/Rx Normal Select 2
(Normal)
•
/Rx ECS Select 1
(Inverted)
To RX ECS Select Relay
•
/Rx ECS Select 2
(Inverted)
To Console Input
The RX ECS select can be used to disable the comparator repeat function. See
details in Section 2 - Repeater Control.