beautypg.com

CTI Products CCU Channel Control Unit User Manual

Page 11

background image

CCU Hardware Reference

Theory of Operation

CTI Products, Inc.

68-11843-105

5

3.2

Section 1 - Main / Standby Base Selection

The following logic diagram of the Main / Standby Base Select section shows the
basic section logic.

Debounce

One-Shot

Debounce

One-Shot

CK +

T

S (Async)

R (Async)

System Reset

Q

Q

CtlI Bit 1 Main/Stby Toggle 1

Ctl Bit 2 Main Base Force On

Ctl Bit 3 Main/Stby Toggle 2

Ctl Bit 4 Stby Base Force On

Stat Bit 1 Main/Stby Base Toggle 1

Stat Bit 3 Main/Stby Base Toggle 2

Stat Bit 2 Main Base Select

Stat Bit 4 Stby Base Select

/Main Base Select

/Stby Base Select

/Main Base Select 2

/Standby Base Select 2

2

1

4

21

Stat Bit 21 Main/Stby Tgl 3

Debounce

One-Shot

(CIB Rx 1)

(CIB Vote 1)

(CIB Dis 7)

Main/Stby Base Toggle 1

22

21

2

Main/Stby Base Toggle 2

Main/Stby Base Toggle 3

20

19

23

31

(CIB Mon 6)

(CIB Fail 1)

(CIB Dis 1)

(CIB Mon 1)

CA-80877-105 CCU Version 105 Logic Section 1

Figure 3 – Main / Standby Base Section Logic


There are three external inputs:

/Main/Standby Toggle 1

(from Console 1)

/Main/Standby Toggle 2

(from Console 2)

/Main/Standby Toggle 3

(from Console 3)


There are four logic outputs:

/Main Base Select 1

(Normal)

to TSAM TXS1

/Main Base Select 2

(Normal)

/Standby Base Select 1

(Inverted)

To TSAM TXS2

/Standby Base Select 2

(Inverted)

To Console Input